5 System Parameters
MICROMASTER 440 Operating instructions
6SE6400-5CA00-0BP0
63
Communication (P0004 = 20)
Par. No.
Parametername
Default
Acc
WS
QC
P0918
CB address
3
2
CT
N
P0927
Parameter changeable via
15
2
CUT
N
r0964[5]
Firmware version data
-
3
-
-
r0965
Profibus profile
-
3
-
-
r0967
Control word 1
-
3
-
-
r0968
Status word 1
-
3
-
-
P0971
Transfer data from RAM to EEPROM
0
3
CUT
N
P2000[3]
Reference frequency
50.00
2
CT
N
P2001[3]
Reference voltage
1000
3
CT
N
P2002[3]
Reference current
0.10
3
CT
N
P2003[3]
Reference torque
0.75
3
CT
N
r2004[3]
Reference power
-
3
-
-
P2009[2]
USS normalization
0
3
CT
N
P2010[2]
USS baudrate
6
2
CUT
N
P2011[2]
USS address
0
2
CUT
N
P2012[2]
USS PZD length
2
3
CUT
N
P2013[2]
USS PKW length
127
3
CUT
N
P2014[2]
USS telegram off time
0
3
CT
N
r2015[8]
CO: PZD from BOP link (USS)
-
3
-
-
P2016[8]
CI: PZD to BOP link (USS)
52:0
3
CT
N
r2018[8]
CO: PZD from COM link (USS)
-
3
-
-
P2019[8]
CI: PZD to COM link (USS)
52:0
3
CT
N
r2024[2]
USS error-free telegrams
-
3
-
-
r2025[2]
USS rejected telegrams
-
3
-
-
r2026[2]
USS character frame error
-
3
-
-
r2027[2]
USS overrun error
-
3
-
-
r2028[2]
USS parity error
-
3
-
-
r2029[2]
USS start not identified
-
3
-
-
r2030[2]
USS BCC error
-
3
-
-
r2031[2]
USS length error
-
3
-
-
r2032
BO: CtrlWrd1 from BOP link (USS)
-
3
-
-
r2033
BO: CtrlWrd2 from BOP link (USS)
-
3
-
-
r2036
BO: CtrlWrd1 from COM link (USS)
-
3
-
-
r2037
BO: CtrlWrd2 from COM link (USS)
-
3
-
-
P2040
CB telegram off time
20
3
CT
N
P2041[5]
CB parameter
0
3
CT
N
r2050[8]
CO: PZD from CB
-
3
-
-
P2051[8]
CI: PZD to CB
52:0
3
CT
N
r2053[5]
CB identification
-
3
-
-
r2054[7]
CB diagnosis
-
3
-
-
r2090
BO: Control word 1 from CB
-
3
-
-
r2091
BO: Control word 2 from CB
-
3
-
-