Connecting cables to the HiPath Wireless Outdoor AP
9034532, October 2009
HiPath Wireless Outdoor AP Installation Guide
27
4 Connecting cables to the HiPath Wireless Outdoor AP
Notes on lightning protection
A suitable lightning conductor is available in the range of accessories for the
HiPath Wireless Outdoor AP (Lightning Protector LP798-1N, Order# 6GK5798-
2LP00-2AA6 from Siemens A&D).
Note:
The requirements of EN61000-4-5, surge immunity tests on power supply
lines, are met only when a Blitzductor is used with 12 V DC and 48 V DC:
• 12 V DC: VT AD 24V type no. 918 402
• 48 V DC: Type no. 919 545 and 919 506 (holder)
Manufacturer: DEHN+SÖHNE GmbH+Co.KG Hans Dehn Str.1 Postfach 1640 D
92306 Neumarkt, Germany.
Warning
Antennas installed outdoors must be within the area covered by a lightning protection system.
Make sure that all conducting systems entering from outdoors can be protected by a lightning
protection potential equalization system.When implementing your lightning protection concept,
make sure you adhere to the VDE 0182 or IEC 62305 standard.
Warning
Installing this lightning protector between an antenna and an HiPath Wireless Outdoor AP is not
adequate protection against a lightning strike. The LP798-1N lightening protector only works
within the framework of a comprehensive lightning protection concept. If you have questions,
consult a qualified specialist company.