19
Regulating the primary air
The primary air is correctly set when the flame is
stable and blue/green.
Proceed as follows:
• Undo the screw.
• Turn the cover clockwise or anticlockwise. The
table below shows the correct setting for the
cover.
• Tighten the screws again.
Reassembling the floor
To reassemble the floor, proceed in the opposite
order and pay attention to the 4 screws in the back
wall of the cooking compartment when inserting the
removable floor.
Type of gas
Setting values
G30/29 mbar