15
Converting the gas type
If the appliance is not already set up for the existing
type of gas, the appliance must be converted.
The conversion to a different type of gas must be
carried out by an authorised expert in accordance
with the applicable regulations.
The type of gas and pressure that was preset at the
factory are indicated on the rating plate on the inside
of the storage compartment flap.
In order to convert to a different type of gas, the
nozzles must be replaced and the low flame and
primary air may have to be adjusted.
Hotplate burners
Replacing the nozzles
Proceed as follows:
• Remove the pan supports.
• Remove the burner lids (A) and burner cups (B)
from the burners (C).
• Remove the nozzle (D) and replace it with an
appropriate nozzle for the new type of gas (see
section “General nozzle table”).
• Replace the gas label with the new label that was
supplied with the nozzle set.
A
B
C
D