Diagnostics and upkeep
6.5 TeleService
CP 1243-7 LTE
128
Operating Instructions, 04/2017, C79000-G8976-C381-03
TeleService server in "Mobile wireless communication settings" of the CP
You configure the following information in the parameter group "Mobile wireless
communications settings" of the CP:
●
Address of the TeleService server
IP address or name of the telecontrol server that can be resolved by DNS or of the
TeleService gateway
●
Port
Port number of the telecontrol server or the TeleService gateway
Users and roles in the global security settings
1.
Open the following page in the project tree:
Global security settings > User management
2.
Role
Open the "Roles" tab
The two tables "Roles" and "Rights of the role" become visible.
If necessary open the "Roles view" if this is hidden by the "Rights of the role" table.
In the "Roles" table (at the top) create a new user-defined role for TeleService.
3.
In the "User" tab create a user that will later be allowed to execute the TeleService
functions for the CP.
Configure the following parameters:
–
User name
Assign the name of the user that will have TeleService rights.
You require the user name at the start of a TeleService session.
–
Authentication method
Select the authentication method "Password" for this user.
–
Password
Assign the password.
You require the password at the start of a TeleService session.
Note:
You specify the password properties of the security functions in the "Password
policies" tab.
You enter the password on the engineering station when starting a TeleService
session.
–
Maximum time of the session
The time that can be configured here is only required for access to SCALANCE S
modules. If the user is set up only for TeleService sessions, you can leave the default
value unchanged.
4.
Click on the "Roles" tab.