Summary of Contents for CP 1243-7 LTE

Page 1: ...____ ___________________ SIMATIC NET S7 1200 TeleControl CP 1243 7 LTE Operating Instructions CP 1243 7 LTE EU CP 1243 7 LTE US 04 2017 C79000 G8976 C381 03 Preface Application and properties 1 LEDs and connectors 2 Installation connecting up commissioning 3 Configuration 4 Program blocks 5 Diagnostics and upkeep 6 Technical specifications 7 Dimension drawings A Approvals B Accessories C Documenta...

Page 2: ...e operated only by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING...

Page 3: ...are product version 2 Firmware version V3 0 Communications processor for connection of the SIMATIC S7 1200 via LTE or UMTS mobile wireless networks North American standard AT T certified Figure 1 CP 1243 7 LTE Behind the top hinged cover of the module housing next to the article number you will see the hardware product version printed as a placeholder X for example X 2 3 4 In this case X would be ...

Page 4: ...ing the device The necessary configuration steps are described in the form of an overview You will also find instructions for operation and information about the diagnostics options of the device New in this issue New hardware product version 2 New functions in the firmware version named above include Sending messages even without telecontrol communication Changed behavior during time of day synch...

Page 5: ...ecurity information Siemens provides products and solutions with industrial security functions that support the secure operation of plants systems machines and networks In order to protect plants systems machines and networks against cyber threats it is necessary to implement and continuously maintain a holistic state of the art industrial security concept Siemens products and solutions only form ...

Page 6: ...ublic disposal sites For environmentally friendly recycling and the disposal of your old device contact a certified disposal company for electronic scrap or your Siemens contact Keep to the local regulations You will find information on returning the product on the Internet pages of Siemens Industry Online Support Link https support industry siemens com cs ww en view 109479891 SIMATIC NET glossary...

Page 7: ... 32 3 Installation connecting up commissioning 33 3 1 Important notes on using the device 33 3 1 1 Notices on use in hazardous areas 33 3 1 2 Notes on use in hazardous areas according to ATEX IECEx 34 3 1 3 Notices regarding use in hazardous areas according to UL HazLoc 35 3 2 Installing the CP and commissioning 35 3 3 Notes on operation 40 4 Configuration 41 4 1 Security recommendations 41 4 2 Co...

Page 8: ...up 72 4 11 6 5 Connection to the telecontrol server 73 4 11 6 6 CP as passive subscriber of VPN connections 73 4 11 6 7 SYSLOG 73 4 11 7 Certificate manager 74 4 11 8 Handling certificates 74 4 12 Data point configuration 76 4 12 1 Data point configuration 76 4 12 2 Datapoint types 83 4 12 3 Syntax of the data point names 84 4 12 4 Process image type of transmission event classes triggers 84 4 12 ...

Page 9: ...leService access 127 6 5 2 Establishment of a TeleService connection 129 7 Technical specifications 133 7 1 General technical specifications 133 7 2 Technical specifications wireless interface CP 1243 7 LTE EU 134 7 3 Technical specifications wireless interface CP 1243 7 LTE US 135 7 4 Pin assignment of the socket for the external power supply 136 A Dimension drawings 137 B Approvals 139 C Accesso...

Page 10: ...Table of contents CP 1243 7 LTE 10 Operating Instructions 04 2017 C79000 G8976 C381 03 ...

Page 11: ...itly stated differently in the following manual the telecontrol communication relates to connections to a telecontrol server with the application TCSB TeleControl Server Basic V3 Changing the mobile wireless standard if the network is not available If the establishment of a connection via a mobile wireless network with the LTE standard fails the CP attempts to dial in to an available network with ...

Page 12: ...n stations via a master station inter station communication and direct communication between stations The CP supports the following services for communication via the mobile wireless network or via the mobile wireless network and the Internet Data services Transfer of process data via mobile wireless networks with the following standards GPRS EDGE General Packet Radio Service The packet oriented s...

Page 13: ...nicates with a higher level control system using the integrated OPC server function Event driven sending of messages using SMS or e mail Via the mobile wireless network the CP sends SMS messages to mobile phones or e mails to PCs with an Internet connection Both types of messages are configured in telecontrol communication in STEP 7 The use of program blocks is not necessary For information on the...

Page 14: ...on examples Page 22 S7 communication Reading writing data from to a CPU via the mobile wireless network is possible if S7 communication is enabled in the configuration of the CP The following instructions are supported PUT GET You will find details on the program blocks in the information system of STEP 7 For S7 communication the CP requires a fixed IP address see section Other services and proper...

Page 15: ...unication or to receive data via Open User Communication the CPU must be reachable via a fixed IP address In this case enter the fixed IP address assigned by the mobile wireless network provider in the same parameter group Time of day synchronization The CP supports various methods of time of day synchronization You will find information in the section Time of day synchronization Page 47 For infor...

Page 16: ... following security functions TeleControl Basic Encrypted telecontrol communication As an integrated unconfigurable security function the TeleControl Basic protocol encrypts the data for transfer You configure the interval of the key exchange between the CP and telecontrol server in STEP 7 in the parameter group Ethernet interface X1 Advanced options Transmission settings Authorized phone numbers ...

Page 17: ...net PROFINET interfaces of the CPU As a result of using the CP as a security module the following additional security functions are accessible to the S7 1200 station on the interface to the external network Firewall IP firewall with stateful packet inspection layer 3 and 4 Firewall also for non IP Ethernet frames according to IEEE 802 3 layer 2 Limitation of the transmission speed Bandwidth limita...

Page 18: ... Communication OUC The maximum number can be divided up as follows into S7 connections Maximum 8 PUT GET OUC connections Maximum 8 TCP connections ISO on TCP connections UDP connections Additional free resources for S7 or OUC connections Maximum 6 Number of connections to NTP servers Max 1 connection to an NTP server Number of possible partners for inter station communication Max 13 CPs as partner...

Page 19: ...ual parts for all configured communications partners The size of the frame memory can be set in STEP 7 See also section Process image type of transmission event classes triggers Page 84 Messages E mail SMS Up to 10 messages can be configured in STEP 7 and sent as e mails or SMS messages Maximum number of characters that can be transferred per SMS message 160 ASCII characters including any value se...

Page 20: ...P refer to the appendix Antenna Page 147 For telecontrol communication a PC with an Internet connection is required for the telecontrol server in the master station If you intend to use TeleService via mobile wireless a TeleService gateway with Internet access is required for configurations without a telecontrol server This is a PC on which the TS Gateway software is installed see appendix TS Gate...

Page 21: ...ess services Local availability of a mobile wireless network in the range of the station A contract with a suitable mobile wireless network provider The contract must allow the transfer of data IP address For communication with the telecontrol server a private fixed or public dynamic IP address assigned by the mobile wireless network provider can be used For direct communication between S7 station...

Page 22: ... or received due to calling the corresponding program blocks of Open User Communication You will find information on the blocks in the section Program blocks for OUC Page 105 you will find the description of the programming in the STEP 7 information system Using a mobile phone a diagnostics SMS can be requested see section Diagnostics options Page 119 For all mobile phones that send SMS messages t...

Page 23: ...ile wireless network The TeleControl Server Basic V3 TCSB application is installed on the telecontrol server in the master station This results in the following use cases Communication between a station and a control room with OPC client The station communicates with the telecontrol server Using its integrated OPC server the telecontrol server exchanges data with the OPC client of the control room...

Page 24: ...bile wireless network and the Internet with the CP in the S7 1200 Since the firewall of the network provider is normally closed for connection requests from the outside a switching station between the remote station and the engineering station is required This switching station can be a telecontrol server or if there is no telecontrol server in the configuration a TeleService gateway TeleService w...

Page 25: ...eless network in a configuration with telecontrol server TeleService with TeleService gateway via LAN The connection between the engineering station and S7 station is via the TeleService gateway The engineering station is connected to the TeleService gateway via LAN Figure 1 5 TeleService via the mobile wireless network with TeleService gateway connection via LAN ...

Page 26: ...ervice with TeleService gateway via the Internet The connection between the engineering station and S7 station is via the TeleService gateway The engineering station is connected to the TeleService gateway via the Internet Figure 1 6 TeleService via the mobile wireless network with TeleService gateway connection via the Internet ...

Page 27: ...of the module housing The socket for the power supply is located on the top of the module The connector for the external antenna is located on the bottom of the module The compartment for inserting the SIM card is located behind the upper hinged cover of the module Opening the housing Open the upper or lower cover of the housing by pulling it down or up as shown in the illustration The covers exte...

Page 28: ...us of the module Table 2 2 LEDs below the upper cover of the housing LED colors Name Meaning red green NETWORK Status of the connection to the mobile wireless network green CONNECT Status of the connection to the master station yellow green SIGNAL QUALITY Signal quality of the mobile wireless network green VPN Status of the VPN connection Note LED colors when the module starts up When the module s...

Page 29: ...n CONNECT green SIGNAL QUALITY yellow green VPN green Meaning Display of the basic statuses of the module Power OFF red Startup flashing red Errors Invalid CP configuration or CP type does not match the configuration data on the CPU green Running RUN without error flashing red Backplane bus error flashing red Missing SIM card flashing red Missing or incorrect PIN Connection to the mobile wireless ...

Page 30: ... RUN flashing green No partner reachable CPU in STOP flashing green Telecontrol configuration exists partner not reachable CPU in RUN mode flashing green Telecontrol configuration exists partner not reachable CPU in STOP mode Quality of the mobile wireless connection Good network 73 51 dBm Medium strength network 89 74 dBm Weak network 109 90 dBm No network 110 dBm flashing red Missing external po...

Page 31: ...oaded flashing red Error loading firmware or Internal error of the CP remedy Power OFF ON 2 3 Electrical connectors 2 3 1 Power supply Power supply The 3 pin socket for the external 24 V DC power supply is located on the top of the module The matching plug ships with the product You will find the pin assignment of the socket in section Pin assignment of the socket for the external power supply Pag...

Page 32: ...s required for communication in the mobile wireless network This is connected via the SMA socket of the CP The SMA socket is located behind the lower front cover of the CP You will find the antenna permitted in the section Accessories Page 147 More detailed information on the electrical connections For technical information on the electrical connections refer to the section Technical specification...

Page 33: ...possible This can be caused for example by lightning strikes or switching of higher loads The connector of the external power supply is not protected from strong electromagnetic pulses To protect it an external overvoltage protection module is necessary The requirements of EN61000 4 5 surge immunity tests on power supply lines are met only when a suitable protective element is used A suitable devi...

Page 34: ...pment is connected to a redundant power supply two separate power supplies both must meet these requirements WARNING EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR COMBUSTIBLE ATMOSPHERE IS PRESENT WARNING EXPLOSION HAZARD SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I DIVISION 2 OR ZONE 2 WARNING When used in hazardous environments corresponding to Clas...

Page 35: ...3 Notices regarding use in hazardous areas according to UL HazLoc WARNING EXPLOSION HAZARD DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON HAZARDOUS This equipment is suitable for use in Class I Division 2 Groups A B C and D or non hazardous locations only This equipment is suitable for use in Class I Zone 2 Group IIC or non hazardous locations only 3 2 Installing the CP and...

Page 36: ...te Inserting and removing the SIM card Do not insert or remove the SIM card while the CP is operating Prior to installation insert the SIM card in the CP Step Execution Notes and explanations 1 Turn off the power supply to the station 2 Release the slide for the SIM card on the bottom of the CP behind the lower cover by gently pressing the release pin 3 Remove the slide from the housing 4 Insert t...

Page 37: ...22 5 mm 16 analog I Os RTD 8 I Os 70 mm 35 mm Communications inter faces Examples CM 1241 RS232 CM 1241 RS485 30 mm 15 mm CM 1243 5 PROFIBUS master CM 1242 5 PROFIBUS slave 30 mm 15 mm CP 124x 7 30 mm 15 mm Width B The distance between the edge of the housing and the center of the hole in the DIN rail mounting clip DIN rail mounting clips All CPUs SMs CMs and CPs can be installed on the DIN rail i...

Page 38: ...nges depend on the position of the installed device You will find the permitted temperature ranges in the section General technical specifications Page 133 Installation of the rack Installation position of the CP Horizontal installation of the rack Vertical installation of the rack Note Connection with power off Only wire up the S7 1200 with the power turned off Note Power supply from the power ou...

Page 39: ... in the section Pin assignment of the socket for the external power supply Page 136 5 Connect the antenna to the SMA socket of the CP Lower surface of the CP Notice Protect the antenna connector using suitable overvoltage protection equipment if the antenna cable is long er than 30 m Protect the antenna connector with suitable lightning protection if you install the antenna outdoors If you install...

Page 40: ...000 G8976 C381 03 3 3 Notes on operation CAUTION Minimum clearance to the device The device may only be operated when the distance between the device or antenna and user is at least 20 cm NOTICE Closing the front panels To ensure interference free operation keep the front panels of the module closed during operation ...

Page 41: ...ns Internet pages Here you will find information on network security Link http www siemens com industrialsecurity Here you will find information on Industrial Ethernet security Link http w3 siemens com mcms industrial communication en ie industrial ethernet security Seiten industrial security aspx You will find an introduction to the topic of industrial security in the following publication Link h...

Page 42: ... for example a password in a DB later remember the following The contents of a DB with know how protection are no longer visible and can only be changed via the source or by direct assignment of parameters Logging function Enable the function in the Security configuration and check the logged events regularly for unauthorized access Passwords Define rules for the use of devices and assignment of p...

Page 43: ... the configuration Port status Open The port is always open and cannot be closed Open according to configuration The port is open if it has been configured Open login when configured As default the port is open After configuring the port the communications partner needs to log in Authentication Specifies whether or not the protocol authenticates the communications partner during access Protocol fu...

Page 44: ...o be transferred input output data to the data points you need to create PLC tags Overview of the configuration steps in STEP 7 Notes No Ethernet network needs to be created for the communication via the mobile wireless network A telecontrol server or a TeleService gateway cannot be configured in STEP 7 Follow the steps below when configuring 1 Create a STEP 7 project 2 Insert the required SIMATIC...

Page 45: ...umbers Call numbers of the nodes that can instigate connection establishment by the CP with an SMS message or call APN Name of the access point APN from the mobile wireless network to the Internet information from the mobile wireless network provider APN user name User name for the access point of the mobile wireless network provider APN password Password for the access point of the mobile wireles...

Page 46: ... the telecontrol server that can be resolved by DNS IPT listener port of the telecontrol server Default setting 55097 If only connections with TCSB are used no direct communication a dynamic IP address can be assigned to the CP by the Internet service provider For addressing a redundant TCSB system refer to the section Partner stations Telecontrol server Page 57 DNS server address es You require t...

Page 47: ...ntification parameter group Security parameter group Project number Station number Password for authentication 4 4 Time of day synchronization Synchronization method of the CP Note Time of day synchronization of the CP With applications that require time of day synchronization e g telecontrol you need to synchronize the time of day of the CP regularly If you do not synchronize the time of day of t...

Page 48: ...hash algorithms MD5 or SHA 1 On the CP you specify the servers used You configure NTP servers of the type NTP secure in the global security settings of STEP 7 Time from the CPU As of V4 2 the CPU synchronizes all CMs CPs of the station with a synchronization cycle of 10 seconds Parameters of the CPU If for the CPU the option CPU synchronizes the modules of the device is enabled all smart modules o...

Page 49: ...ing an external time source the S7 1200 station can obtain the current time of day both via the CPU as well as via a CP With the S7 1200 there is no forwarding of the time of day from the station to the subnet Note Recommendation Time of day synchronization only by 1 module Only have the time of day of the station from an external time source synchronized by a single module so that a consistent ti...

Page 50: ...munication with the CPU you can set whether or not the current time of day of the CP will be made available to the CPU via a PLC tag For TLC tags see parameter group Communication with the CPU of the CP CP firmware V2 1 77 and CPU firmware V4 2 If both modules in the station have the named firmware versions the time of day of the CP is automatically forwarded to the CPU Since the CPU automatically...

Page 51: ...t connection to the interface of the CPU however remains possible To use TeleService via the mobile wireless network you need to enable this function Enabling S7 communication Enables the functions of S7 communication with a SIMATIC S7 on the CP If you configure S7 connections to the relevant station and these run via the CP you will need to enable this option on the CP Enabling SMS On the CP enab...

Page 52: ...er of the SIM card leave the box empty Configured number If you want to use a different SMSC enter the phone number of this SMSC Note the following Note Permanent storage of the SMSC number If you configure an SMSC number the CP no longer accesses the SMSC data of the SIM card This is also the case if you delete the SMSC number from the configuration again Recommendation When you configure an SMSC...

Page 53: ... interface In STEP 7 the Ethernet interface is used as a placeholder for the configuration of various address and monitoring parameters Ethernet addresses Enter you configure IP address of the CP and if applicable the network connection If you enable security functions for example when using telecontrol communication for reasons of consistency you need to network the CP To do this create any Ether...

Page 54: ...nnection monitoring time occurs again with the individual partners in the parameter group Connection to partner This parameter applies only to the individual partner The value of 180 seconds preset on the Ethernet interface is adopted for the individual partners If for any reason you want to change the value of the TCP connection monitoring time for individual partners you can adapt the value for ...

Page 55: ...g 10 s Permitted range of values for the basic value 10 300 s Example A configured basic value 20 results in the following intervals waiting times between the attempts to re establish a connection three times 20 s three times 40 s three times 80 s etc up to max 900 s Note If the partner cannot be reached connection establishment via the mobile wireless network can take several minutes This may dep...

Page 56: ...h the CP expects a reply from the telecontrol server If the CP does not receive a reply from the Telecontrol server within the monitoring time it terminates and re establishes the connection Default setting 30 s Permitted range 0 65535 s If you enter 0 zero the function is disabled Key exchange interval Here you enter the interval in hours after which the key is exchanged again between the CP and ...

Page 57: ... of the DSL router via which the telecontrol server can be reached from the Internet Set the port forwarding on the DSL router so that the public IP address external network is led to the virtual IP address of the TCSB server PCs internal network The station does not therefore receive any information telling it which of the two computers of the redundancy group it is connected to Connection monito...

Page 58: ...P connection monitoring time for individual partners you can adapt the value for every partner individually in Partner stations If for example you want to check the connection at shorter intervals reduce the value If disruptions or delays occur often when transferring in your mobile wireless network it may be advisable to increase the value TCP keepalive monitoring time If the value configured her...

Page 59: ...s the status of the communication to the remote partner Bit 0 of PLC tag for partner status data type WORD is set to 1 if the partner can be reached Bit 1 is set to 1 if all the paths to the remote partner are OK useful with redundant paths Bits 2 3 indicate the status of the send buffer frame memory The following values are possible 0 Send buffer OK 1 Send buffer threatening to overflow more than...

Page 60: ...s the protocol specific acknowledgement mechanisms are used 4 8 3 Connection establishment Connection establishment Connection to the telecontrol server The connection to the telecontrol server is always established by the CP If a connection established by the CP is interrupted the CP automatically attempts to re establish the connection Note the settings for re establishing the connection in STEP...

Page 61: ...ations partners You specify the partner CP for inter station communication with the parameters Project Station and Slot Project Here enter the project number of the CP in the partner station You will find the parameter in the parameter group Security CP identification on the partner CP Station number Here enter the station number of the CP in the partner station You will find the parameter in the ...

Page 62: ...ider of the mobile wireless network recommended procedure The requirement is that the network provider operates a DNS server in the network Configuration of a DNS server If you want to use a different DNS server enter its IP address In this case DNS servers of the network provider are not taken into account The addresses of the DNS servers can be configured in the IPv4 or IPv6 format 4 10 Communic...

Page 63: ...tus of the telecontrol communication of the CP CP time CP time to CPU Using this function the CP can synchronize the CPU clock You will find details in the STEP 7 information system CP diagnostics In the parameter group CP diagnostics you have the option of reading out advanced diagnostics data from the CP using PLC tags Diagnostics trigger tag If you want to use advanced CP diagnostics you need t...

Page 64: ...ality of the local mobile wireless network as a dBm value NETWORK LED PLC tag data type UInt for the status of the connection for the data service in the mobile wireless network Meaning of the values decimal 0 Booked out of the network 1 Wrong PIN 2 Wrong defective SIM card or not plugged in 3 Waiting for PIN no PIN configured 4 Booked into the network Date of last successful logon to network PLC ...

Page 65: ...f security functions are enabled you will find the following parameter groups here CP identification Here you configure parameters for authenticating the CP with the telecontrol server You will find details below Time of day synchronization For the configuration of the time of day synchronization read the section Time of day synchronization Page 47 Authorized phone numbers You will find details be...

Page 66: ...P 7 project TCSB evaluates project numbers from 1 2000 If you change the project number this parameter is changed for all CPs in the STEP 7 project Station number For each S7 1200 station with a telecontrol CP an individual station number is configured TCSB evaluates station numbers from 1 8000 Telecontrol password Password for the authentication of the CP on the telecontrol server 8 29 characters...

Page 67: ...wall settings of the CP In advanced firewall mode Security Firewall IP rules select the action Allow for both communications directions of the VPN tunnel 4 11 3 Authorized phone numbers SMS messages received only from subscribers with an authorized phone number The CP only accepts an SMS if the sending communication partner is authorized based on its phone number These phone numbers are configured...

Page 68: ...your e mail provider offers both options STARTTLS SSL TLS you should use STARTTLS with port 587 Port no 465 By using SSL TLS SMTPS the module sends encrypted e mails to the SMTP server of your e mail service provider Ask your e mail service provider which option is supported Importing the certificate with encrypted transfer To be able to use encrypted transfer you need to load the certificate of y...

Page 69: ... features of the VPN tunnel is that it forwards all frames even from protocols of higher layers HTTP FTP telecontrol protocols of the application layer etc The data traffic between two network components is handled unrestricted through a physical network This allows networks to be connected together via an intermediate network VPN ensures information security in networked automation systems Proper...

Page 70: ...mobile wireless network provider You must also make sure that apart from this IP address the ports required for VPN are reachable from the Internet 4 11 6 3 Creating a VPN tunnel for S7 communication between stations Requirements To allow a VPN tunnel to be created for S7 communication between two S7 stations or between an S7 station and an engineering station with a security CP for example CP 162...

Page 71: ...settings of the CP click the User login button Result A new window opens 2 Enter the user name password and confirmation of the password 3 Click the Logon button You have created a new security user The security functions are now available to you With all further logons log on as user Select the Activate security features check box After logging on you need to select the Activate security features...

Page 72: ...e the telecontrol server is the time master if telecontrol communication is enabled Configure the properties of the VPN group 1 Double click on the newly created VPN group Result The properties of the VPN group are displayed under Authentication 2 Enter a name for the VPN group Configure the settings of the VPN group in the properties These properties define the default settings of the VPN group t...

Page 73: ...for VPN connection establishment with passive subscribers If the CP is connected to another VPN subscriber via a gateway you need to set the permission for VPN connection establishment to Responder This is the case in the following typical configuration VPN subscriber active gateway dyn IP address Internet gateway fixed IP address CP passive Configure the permission for VPN connection establishmen...

Page 74: ...ed security functions are supplied with certificates The STEP 7 project is the certification authority Note No certificate with security functions disabled If the security functions of the CP are disabled in the STEP 7 project no certificate will be generated for the CP For the secure transfer of e mails via SSL TLS and SSL certificate is created for the CP It is visible in STEP 7 in Global securi...

Page 75: ...arameter group Security Certificate manager 3 In the table double click on the cell with the entry Add new The Certificate manager table of the Global security settings is displayed 4 In the table select the required third party certificate and to adopt it click the green check mark below the table The selected certificate is displayed in the local table of the CP Only now will the third party cer...

Page 76: ...e programmed for telecontrol modules with data point configuration to transfer user data between the station and communications partner The data areas in the memory of the CPU intended for communication with the communications partner are configured data point related on the module Each data point is linked to a PLC tag or the tag of a data block Requirement Created PLC tags and or data blocks DBs...

Page 77: ...e module to the CPU via the PLC tags or DBs Configuring the data points and messages in STEP 7 You configure the data points in STEP 7 in the data point and message editor You can find this using the project tree Project directory of the relevant station Local modules CP Figure 4 1 Configuring data points and messages By double clicking on the entry the data point or message editor Using the two e...

Page 78: ... the data point a PLC tag can serve as the data source For the assignment you have the following options Click on the table symbol in the cell of the PLC tag column All configured PLC tags and the tags of the created data blocks are displayed Select the required data source with the mouse or keyboard Click the symbol A selection list of the configured PLC Tags and the blocks is displayed From the ...

Page 79: ...right mouse key Optimize width Optimize width of all columns If you move the cursor close to the limit of a column header the following symbol appears When it does click immediately on the column header The column width adapts itself to the broadest entry in this column Showing hiding columns You call this function using the shortcut menu that opens when you click on a column header with the right...

Page 80: ...ames made up of the station name and module name The file itself contains the following information in addition to the data point information Module name Module type CPU name CPU type Editing the data point information You can edit the data point information in an exported CSV file This allows you to use this file as a configuration template for many other stations If you have a project with many ...

Page 81: ...s required for the data points have been created Note that when you import a CSV file all the data points existing on the module will be deleted and replaced by the imported data points Select a module and select the import function from the shortcut menu of the module The import dialog opens in which you select the required CSV file in the file directory If the information on the assignment of th...

Page 82: ...mport is aborted when a module or CPU name is different from the data in the CSV file Note Modules with the same telecontrol protocol are compatible with each other TeleControl Basic All SIMATIC NET modules with the TeleControl Basic protocol CP 1243 1 CP 1242 7 GPRS V2 CP 1243 7 LTE CP 1542SP 1 IRC ST7 CP 1243 8 IRC TIM modules capable of ST7 DNP3 CP 1243 1 CP 1243 8 IRC TIM modules capable of DN...

Page 83: ... Data point types Table 4 1 Supported data point types and compatible S7 data types Format memory requirements Data point type Direction S7 data types Address area Bit Digital input in Bool I Q M DB Digital output in Bool Q M DB Byte Digital input in Byte Char USInt I Q M DB Digital output out Byte Char USInt Q M DB Integer with sign 16 bits Analog input in Int I Q M DB Analog output out Int Q M D...

Page 84: ... applications in UTC format 48 bits and contain milliseconds 4 12 3 Syntax of the data point names Character set for data point names When you create a data point a preset name DataPoint_n is adopted In the data point table and in the General tab of the data point you can change the name of the data point When assigning names only ASCII characters from the band 0x20 0x7e no 32 126 may be used with...

Page 85: ... are configured as an event The maximum size of the send butter can be found in the section Configuration limits and performance data Page 18 The configured number of events is divided equally among all configured and enabled communications partners For information on the configuration refer to the parameter Frame memory size in the section Communication with the CPU Page 62 If the connection to a...

Page 86: ...s IDs of data points Page 87 Example When the value of a data point configured as an event is updated during startup of the station by reading the CPU data for the first time the status RESTART of this data point changes bit status change 1 0 This leads to generation of an event When data points are configured as an event via the Type of transmission parameter the following event classes are avail...

Page 87: ...rigger fires or after a delay depends on the setting of the parameter Transmission mode in the Trigger tab of the data point Spontaneous The value is transferred immediately Conditional spontaneous The value is transferred only when one of the two following conditions is fulfilled The telecontrol server queries the station The value of another event with the transmission mode Unsolicited is transf...

Page 88: ...Example If the value of the status RESTART of a data point configured as an event changes form 1 value not yet updated to 0 value updated when the station starts up this causes an event to be generated 4 12 6 Data point index Configuration of the data point index Within a CP the indexes of the data point classes must comply with the following rules Input The index of a data point of the type input...

Page 89: ...es High priority read jobs The values of input data points with the scan priority High priority are read in every scan cycle Low priority read jobs Some of the values of input data points with the scan priority Low priority are read in every scan cycle The number of values read per cycle is specified for the CP in the Communication with the CPU parameter group with the Max number of read jobs para...

Page 90: ... of the data point is saved when a configurable trigger signal is fired For the trigger signal the edge change 0 1 of a trigger tag is evaluated that is set by the user program When necessary a separate trigger tag can be configured for each data point Resetting the trigger tag in the bit memory area DB If the memory area of a trigger tag is in the bit memory or in a data block the CP resets the t...

Page 91: ... mode Spontaneous is transferred 4 12 9 Threshold value trigger Note Threshold value trigger Calculation only after Analog value preprocessing Note that the analog value preprocessing is performed before the check for a configured threshold value and before calculating the threshold value This affects the value that is configured for the threshold value trigger Note No Threshold value trigger if M...

Page 92: ...the threshold value band Last saved value threshold value As soon as the process value reaches the upper or lower limit of the threshold value band the value is saved The newly saved value serves as the basis for calculating the new threshold value band Integrative method The integration threshold value calculation works with a cyclic comparison of the integrated current value with the last stored...

Page 93: ...ion of the process value of approximately 0 5 should fire the trigger then with the behavior of the process value shown here a threshold value of approximately 1 5 2 5 would need to be configured 4 12 10 Analog value preprocessing CPs with data point configuration support analog value preprocessing For analog value data points some or all of the functions described below can be configured Requirem...

Page 94: ...erating Instructions 04 2017 C79000 G8976 C381 03 Sequence of the analog value preprocessing options The values of analog inputs configured as an event are processed on the CPU according to the following scheme Figure 4 5 Sequence of the analog value preprocessing ...

Page 95: ...int are read in a 100 millisecond cycle and totaled The number of read values per time unit depends on the read cycle of the CPU and the CPU scan cycle of the CP The mean value is calculated from the accumulated values as soon as the transfer is triggered by a trigger Following this the accumulation starts again so that the next mean value can be calculated The mean value can also be calculated if...

Page 96: ...e if values from the underrange should not be transferred as real measured values Exception With process data from input modules the value 32768 8000h for wire break of a live zero input is transferred With a software input on the other hand all values lower than zero are corrected to zero Fault suppression time Requirements for the function Configuration of the threshold trigger for this data poi...

Page 97: ...sible or useful if these finished values also adopt the values listed above 32767 7FFFh or 32768 8000h in the overflow or underflow range If this is not the case the parameter should not be configured for preprocessed values For finished values preprocess in the CPU the limits for the overflow and underflow can be freely assigned Smoothing factor Requirements for the function Configuration of the ...

Page 98: ...upport status identifiers if the limit value is overshot or undershot the status identifier of the data point is set for measured range violation indicated below as the identifier OV This status identifiers are described in the section Status IDs of data points Page 87 The OV bit of the status identifier of the data point is set as follows when the relevant analog value is transferred Limit value ...

Page 99: ...wo options delete the previously configured values limit values from the input boxes and then disable the relevant option Recommendation for quickly fluctuating analog values If the analog value fluctuates quickly it may be useful to smooth the analog value first if limit values are configured 4 12 11 Partner stations Configuring the inter station communication 4 12 11 1 Options for specifying the...

Page 100: ...g data point of CP 1 Once again both have an identical data point index 4 13 Messages Configuration of the messages If important events occur the CP can send messages The following are configurable SMS The recipient can be a mobile phone or an S7 1200 E mails The recipient can be a PC with an Internet connection or an S7 1200 You configure the messages with the message editor of the CP You can fin...

Page 101: ...ion Communication types Enable SMS Configuration of the SMSC Mobile wireless communication settings see above Configuring the SMS Message editor see above Configuring e mails Additional required information Access data of the SMTP server Address port number user name password When using STARTTLS or SSL TLS Certificate of the e mail service provider E mail addresses of the recipients You create the...

Page 102: ...ory or in a data block the trigger bit is reset to zero when the message is sent In all other cases you need to reset the trigger bit with the user program CPU changes to STOP CPU changes to RUN Connection to a partner interrupted Triggers the sending of the message when the connection to a partner is interrupted Connection to a partner established Triggers the sending of the message when the conn...

Page 103: ...f the type DWORD for the processing status Include value If you enable the option the CP sends a value for the placeholder from the memory area of the CPU in the message To do this enter as a placeholder for the value to be sent in the message text Select a PLC tag whose value will be integrated in the message The value is entered in the message text instead of the placeholder can be a placeholder...

Page 104: ...rating Instructions 04 2017 C79000 G8976 C381 03 Entered as ASCII character sets hexadecimal value and character name 0x20 Space 0x21 0x5F 0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z _ 0x61 0x7E a b c d e f g h i j k l m n o p q r s t u v w x y z 0x7C 0x7E ...

Page 105: ...ata via program blocks the CP requires a fixed IP address assigned by the mobile wireless network provider Note Different program block versions Note that in STEP 7 you cannot use different versions of a program block in a station Supported program blocks for OUC The following instructions in the specified minimum version are available for programming Open User Communication TSEND_C V3 0 TRCV_C V3...

Page 106: ... specified by the system data type SDT Creating an SDT for the data blocks Create the SDT required for every connection description as a data block global DB You generate the SDT type by entering the name e g TCON_Phone in the Data type box manually in the declaration table of block instead of selecting an entry from the Data type drop down list The corresponding SDT is then created with its param...

Page 107: ...tion must be established for each communications partner even if identical blocks of data are being sent After a successful transfer of the data a connection can be terminated A connection is also terminated by calling TDISCON Note Connection abort If an existing connection is aborted by the communications partner or due to disturbances on the network the connection must also be terminated by call...

Page 108: ...llowing special feature in the TCON_PHONE block If you enter an asterisk after the phone number body in the PhoneNumber parameter of the TCON_Phone block the asterisk acts as a placeholder for all authorized phone numbers with this phone number body You configure the phone numbers authorized for access to the CP in STEP 7 in the Security parameter group of the CP Message text to be sent in the DAT...

Page 109: ...PHONE To store the received data from 10 SMS messages you need to create an adequately large structure 2000 bytes for the DATA parameter of the receiving block As described above the structure has the following organization Received data SMS 1 DTL String 22 String 160 Byte Received data SMS 2 DTL String 22 String 160 Byte to Received data SMS 10 DTL String 22 String 160 Byte The received data of e...

Page 110: ...nging configuration data of the CP Meaning With the program block TC_CONFIG you can modify parameters of a the CP configured in STEP 7 The configured values are not overwritten retentively The overwritten values remain valid until TC_CONFIG is called again or until the station starts up again cold restart after cycling power If the STEP 7 configuration data of the CP needs to be changed permanentl...

Page 111: ...lues Description REQ INPUT BOOL 0 1 The processing of the block is started and the status codes initialized on a rising edge Updating of the DONE ERROR and STATUS status codes when there is no positive edge INTERFACE INPUT HW_Interface WORD Reference to the interface of the local CP CONFIG INOUT VARIANT See also IF_CONF SDT for telecontrol configuration data Reference to the memory area with the c...

Page 112: ...combinations of DONE and ERROR in the following table The codes DONE ERROR and STATUS The following table shows the condition codes formed based on DONE ERROR and STATUS that must be evaluated by the user program DONE ERROR STATUS Meaning 1 0 0000H Job executed without errors 0 0 7000H No job processing active first block call 0 0 7001H Job processing started first block call 0 0 7002H Job process...

Page 113: ... parameters of the CP within the IF_CONF DB in one or more structures each with one or more fields You will need to type in the data types of the fields using the keyboard They are not displayed in the selection list The data types are not case sensitive Follow the steps below to create IF_CONF 1 Create a data block of the type global DB with block access Standard 2 Create a structure data type St...

Page 114: ...nt configuration data The permanent configuration data is replaced by the parameter fields of IF_CONF APN settings In STEP 7 the corresponding data is located in the Mobile wireless communications settings parameter area Table 5 3 IF_CONF_APN Parameter Data type Initial value Description Id UINT 4 ID of the parameter field Length UINT Length of the parameter field in bytes 174 Mode UINT Validity 1...

Page 115: ...server not relevant SMSC In STEP 7 the corresponding data can be found in the parameter area Mobile wireless communications settings Services and settings Table 5 6 IF_CONF_SMS_Provider Parameter Data type Initial value Description Id UINT 10 ID of the parameter field Length UINT Length of the parameter field in bytes 28 Mode UINT Validity 1 2 see above general parameters SMSProvider STRING 20 Sub...

Page 116: ...ove general parameters Provider 1 5 ARRAY 1 5 of STRING 6 Alternative mobile wireless networks with priority 1 to 5 into which the CP dials Up to 5 networks can be config ured No 1 with highest priority no 5 with lowest priority Entry of the Public Land Mobile Network PLMN of the network provider consisting of Mobile Country Code MCC and Mobile Network Code MNC Example test network of Siemens AG 2...

Page 117: ... data of the CP CP 1243 7 LTE Operating Instructions 04 2017 C79000 G8976 C381 03 117 Parameter Data type Initial value Description RemotePort UINT Port of the engineering station Rank UINT Priority of the server 1 or 2 1 server 1 2 server 2 not relevant ...

Page 118: ...Program blocks 5 4 IF_CONF SDT for the configuration data of the CP CP 1243 7 LTE 118 Operating Instructions 04 2017 C79000 G8976 C381 03 ...

Page 119: ...stics tab in the Inspector window Here you can obtain the following information about the online status of the selected module STEP 7 Diagnostics functions in the Online Online and diagnostics menu Using the online functions you can read diagnostics information from the CP from an engineering station on which the project with the CP is stored If you want to operate online diagnostics with the stat...

Page 120: ... seconds With the function Disable protocol trace the logging is stopped and the data is written to a logging file With the function Save you can save the log file on the engineering station and then analyze it Device specific events Information on CP internal events Time Information on the time on the device Functions group Saving service data The function serves for logging of internal processes...

Page 121: ...tempted dial in to the mobile wireless network was not successful Attach is sent Name of the current mobile wireless network IP address of the CP Signal strength of the mobile wireless network good Good signal quality 73 51 dBm medium Medium signal quality 89 74 dBm weak Bad signal quality 109 90 dBm no signal Signal too weak to be received 110 dBm Received Signal Strength Indication RSSI Received...

Page 122: ...g destination phone number number not reachable Table 6 2 E mails Meaning of the status ID output in hexadecimal format Status Meaning 0000 Transfer completed free of errors 82xx Other error message from the e mail server Apart from the leading 8 the status corresponds to the three digit error number of the SMTP protocol 8401 No channel available Possible cause There is already an e mail connectio...

Page 123: ...xecuted Mailbox not available unreachable Try again later 84xx Other error message from the e mail server Apart from the leading 8 the status corresponds to the three digit error number of the SMTP protocol 8500 Syntax error Command unknown This also includes the error of having a command chain that is too long The cause may be that the e mail server does not support the LOGIN authentication metho...

Page 124: ...CPU on the Internet page of Industry Online Support shown above Loading the firmware with the online functions of STEP 7 via a WAN Downloading the firmware via the Web server of the CPU as of CPU firmware version V4 0 You can recognize that firmware is being loaded by the flashing LEDs of the CP see section LEDs Page 28 The last two methods are described below Loading the firmware with the online ...

Page 125: ...dministration with the required rights You need to assign the right to perform firmware updates in the access level The procedure for establishing a connection to the Web server depends on whether you have enabled or disabled the Allow access only using HTTPS option in the General parameter group Connection establishment with HTTP Procedure if the Allow access only using HTTPS option is disabled C...

Page 126: ...rver the next time you can log in with the Web server without downloading the certificate using HTTP Connection establishment with HTTPS 1 Connect the PC on which the new firmware file is located to the CPU via the Ethernet interface 2 Enter the address of the CPU in the address box of your Web browser https IP address 3 Press the Enter key The start page of the Web server opens 4 Continue as desc...

Page 127: ...ng the devices The STEP 7 project data of the CP is stored on the local CPU If there is a fault on the device this allows simple replacement of this communications module without needing to load the project data to the station again When the station starts up again the new CP reads the project data from the CPU If you replace a module remember to take the SIM card from the old module and insert it...

Page 128: ...by the Rights of the role table In the Roles table at the top create a new user defined role for TeleService 3 In the User tab create a user that will later be allowed to execute the TeleService functions for the CP Configure the following parameters User name Assign the name of the user that will have TeleService rights You require the user name at the start of a TeleService session Authenticatio...

Page 129: ...s itself with its phone number These phone numbers are configured for the CP in STEP 7 in the Authorized phone numbers list in the security settings A phone number entered here gives the sender the right to trigger connection establishment If only an asterisk is entered in the list the CP accepts SMS messages from all senders An asterisk after a phone number body authorizes connection establishmen...

Page 130: ...llowing when establishing TeleService connections via mobile wireless Note TeleService only by a TIA Portal instance You can operate TeleService with a certain S7 station only from a single engineering station TIA Portal instance STEP 7 project TeleService using several engineering stations at the same time with a station is not possible TeleService with several engineering stations with different...

Page 131: ...hoose the entry TeleService via telecontrol in the Type of interface drop down list 4 Choose the entry TeleService board in the PG PC interface drop down list 5 Click on the icon next to the PG PC interface drop down list The Establish remote connection via telecontrol dialog box opens 6 Make the necessary entries in this dialog You will find information on the necessary entries in the tooltips of...

Page 132: ... up SMS to make the station establish a TeleService connection The phone number of the phone must be configured on the CP as Authorized phone numbers Send an SMS to the phone number of the CP with the following text Text for the wake up SMS message for establishing a connection via the first configured TeleService server TELESERVICE or TELESERVICE 1 Text for the wake up SMS message for establishin...

Page 133: ... 24 VDC Permitted range 19 2 28 8 V Design Terminal block with plug 3 terminals Cable cross section Minimum Maximum 0 14 mm2 AWG 25 1 5 mm2 AWG 15 Max tightening torque of the screw terminals 0 45 Nm 4 lb in Electrical isolation Power supply unit to internal circuit 710 VDC for 1 minute Current consumption typical From 24 VDC external 120 mA From the S7 1200 backplane bus 150 mA Effective power lo...

Page 134: ...witch panel You will find additional functions and performance data in the section Application and properties Page 11 7 2 Technical specifications wireless interface CP 1243 7 LTE EU Table 7 2 Technical specifications of the wireless interface Technical specifications CP 1243 7 LTE EU Article number 6GK7 243 7KX30 0XE0 Frequency bands Supported frequency bands LTE B3 1800 MHz B7 2600 MHz B20 800 M...

Page 135: ...smission speed Downlink 85 6 kbps Uplink 85 6 kbps SMS Mode outgoing MO Service Point to point 7 3 Technical specifications wireless interface CP 1243 7 LTE US Table 7 3 Technical specifications Technical specifications CP 1243 7 LTE US Article number 6GK7 243 7SX30 0XE0 Frequency bands Supported frequency bands LTE B2 1900 MHz B4 1700 MHz B5 850 MHz B17 700 MHz UMTS HSDPA B2 1900 MHz B5 850 MHz G...

Page 136: ...cheme 1 to 9 GMSK Transmission speed Downlink 236 8 kbps Uplink 236 8 kbps GPRS Properties Multislot class 10 end device class B coding scheme 1 to 4 GMSK Transmission speed Downlink 85 6 kbps Uplink 85 6 kbps SMS Mode outgoing MO Service Point to point 7 4 Pin assignment of the socket for the external power supply Figure 7 1 Socket for the external 24 VDC power supply view from above Table 7 4 Pi...

Page 137: ...CP 1243 7 LTE Operating Instructions 04 2017 C79000 G8976 C381 03 137 Dimension drawings A Note All dimensions in the drawings of the CP are in millimeters Figure A 1 Front view ...

Page 138: ...Dimension drawings CP 1243 7 LTE 138 Operating Instructions 04 2017 C79000 G8976 C381 03 Figure A 2 Side view left Figure A 3 From above ...

Page 139: ...he Council of February 26 2014 on the approximation of the laws of the Member States concerning equipment and protective systems intended for use in potentially explosive atmospheres 1999 5 EC R TTE Directive of the European Parliament and of the Council of 9 March 1999 on Radio Equipment and Telecommunications Terminal Equipment and the mutual recognition of their conformity 2011 65 EU RoHS Direc...

Page 140: ...ill find on the supplied data medium and on the Internet at the following address Link zone2 https support industry siemens com cs ww en view 78381013 ATEX Valid only for theCP 1243 7 LTE EU 6GK7 243 7KX30 0XE0 The CP meets the requirements of the EC directive 2014 34 EU Equipment and Protective Devices for Use in Potentially Explosive Atmospheres ATEX approval II 3 G Ex nA II T4 Gc Test number KE...

Page 141: ...1 Electromagnetic compatibility and radio spectrum matters ERM Electromagnetic compatibility EMC for radio equipment and services Part 3 Specific conditions for wireless devices with a low range SRD for use on frequencies between 9 kHz and 246 GHz ETSI EN 301 489 7 V1 3 1 Electromagnetic compatibility and radio spectrum matters ERM Electromagnetic compatibility for radio equipment and services Par...

Page 142: ...ial requirements of article 3 2 of the R TTE directive ETSI EN 301 511 V9 0 2 Global system for mobile communication GSM Harmonized standard for mobile phones in the GSM 900 and GSM 1800 bands covering essential requirements of article 3 2 of the R TTE directive ETSI EN 301 908 1 V6 2 1 IMT cellular networks Harmonized standard covering the essential requirements of article 3 2 of the R TTE direct...

Page 143: ...C Underwriters Laboratories Inc meets ANSI ISA 12 12 01 Nonincendive Electrical Equipment for Use in Class I and II Division 2 and Class III Divisions 1 and 2 Hazardous Classified Locations CAN CSA C22 2 No 213 M1987 1st Ed R2013 Non Incendive Electrical Equipment for Use in Class I Division 2 Hazardous Locations APPROVED for Use in Cl 1 Div 2 GP A B C D T4A Ta 20 C 70 C Cl 1 Zone 2 GP IIC T4 Ta 2...

Page 144: ...otection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference ...

Page 145: ...lid only for theCP 1243 7 LTE EU 6GK7 243 7KX30 0XE0 Customs union of Russia Belarus and Kazakhstan Declaration of the conformity according to the technical regulations of the customs union TR CU RF Telecom Mexico Valid only for the CP 1243 7 LTE US 6GK7 243 7SX30 0XE0 La operación de este equipo está sujeta a las siguientes dos condiciones 1 es posible que este equipo o dispositivo no cause inter...

Page 146: ...itted to the relevant authorities and approval centers for approvals relating to specific markets and applications If you require a list of the current approvals for individual devices consult your Siemens contact or check the Internet pages of Siemens Industry Online Support Link https support industry siemens com cs ww en ps 15924 cert ...

Page 147: ... 2G and UMTS networks 3G weatherproof for indoor and outdoor areas IP65 40 70 C 5 m connecting cable connected permanently to the antenna SMA connector includ ing installation bracket screws wall plugs You will find detailed information in the documentation of the device You will find this on the Internet on the pages of Siemens Industry Online Support at the following address Link https support i...

Page 148: ...provider Configuration of the SMS gateway provider With the help of TS Gateway SMS gateway providers are configured that are necessary for the sending of SMS messages to the remote S7 stations Note TS Gateway only for TeleService TS Gateway is used only for the TeleService function via the mobile wireless network No connections to the remote stations can be monitored and no process data can be tra...

Page 149: ...for TeleService via a TeleService gateway Engineering station connected to a LAN or with Internet access TeleService using mobile wireless is possible on an engineering station with the STEP 7 project that contains the remote station with the mobile wireless CP STEP 7 version required for TeleService via the mobile wireless network V13 SP1 SIMATIC S7 1200 CPU with firmware version as of V4 1 Mobil...

Page 150: ...Accessories C 2 TS Gateway CP 1243 7 LTE 150 Operating Instructions 04 2017 C79000 G8976 C381 03 ...

Page 151: ...l also find the product information in the Siemens Industry Mall at the following address Link https mall industry siemens com Manuals on the Internet You will find SIMATIC NET manuals on the Internet pages of Siemens Industry Online Support Link https support industry siemens com cs ww es ps 15247 man Go to the required product in the product tree and make the following settings Entry type Manual...

Page 152: ... TS Gateway Version V3 Operating Instructions Siemens AG Link https support industry siemens com cs ww en ps 15918 man 4 SIMATIC NET TeleControl Server Basic Version V3 Operating Instructions Siemens AG Link https support industry siemens com cs ww en ps 15918 man 5 SIMATIC NET Industrial Ethernet Security Security basics and applications Configuration manual Siemens AG Link https support industry...

Page 153: ... version 3 Forced image mode 85 Frame memory 19 85 G Gateway 73 Glossary 6 H Hardware product version 3 I Image memory 85 IMEI 3 Importing a certificate e mail 68 Inserting removing a SIM card 36 Instructions OUC 105 Inter station communication 13 23 Inter station communication configuration 61 IP address fixed 70 IP configuration 15 L Logging server 75 N NTP 48 NTP secure 48 IPsec tunnel O Online...

Page 154: ...uration 101 Number of messages 19 Programming OUC 105 Reception 67 SMTPS 68 SSL TLS 68 STARTTLS 68 Static values 85 STEP 7 version 20 SYSLOG 73 T TCSB 4 TeleService 119 TeleService gateway 20 TeleService via mobile wireless 14 Time stamp 19 84 Time of day synchronization 15 Training 6 Transmission mode 87 91 Trigger tag resetting 90 TS Gateway 20 149 U Unsolicited 87 91 User data 19 V VPN 19 69 W ...