If the motor has to be transported, please observe the information and instructions in the
chapter "Transport (Page 27)".
Risk of explosion as a result of inadmissible repair work
Repairs are only permissible within the scope of the work described in these operating
instructions. Otherwise an explosion can occur in an explosive atmosphere. This can result in
death, serious injury or material damage.
● For repairs to go beyond this scope, please contact the Service Center.
See also
Service and Support (Page 111)
Maintenance and repair for machines, type of protection "Ex d/Ex db"
The machine marking based on IEC / EN 60079–0 was supplemented by the "X" symbol.
● Maintain the special conditions for repairs. The gap dimensions for the electric machine do
not comply with the standardized values in IEC / EN 60079–1. For repair work, obtain the
gap dimensions of the electrical machine from the manufacturer.
● Perform maintenance, repair and modification work on explosion-protected machines in
strict compliance with the corresponding national health and safety legislation, the safety
instructions and descriptions in the general maintenance instructions.
Work influencing explosion protection must be carried out by the manufacturer or by a specialist
workshop for electrical machinery authorized by the manufacturer. This includes the following
operations, for example:
● Repairs to the stator or rotor windings and to the terminals
● Repairs to the ventilation system
● Repairs to the bearings
● Dismantling machines with flameproof enclosures
● Connection work carried out in the terminal box
The operations must be identified by an additional repair plate carrying the following
information:
● Date
● Company carrying out repair
● Type of repair
● Reference number of the repair technician regarding repair work
Maintenance
9.4 Corrective Maintenance
SIMOTICS HV C 1NB1402-2AA84-4CA0-Z
Operating Instructions 06/2018
95
Summary of Contents for 1NB1402-2AA84-4CA0-Z
Page 2: ...26 06 2018 15 34 V3 00 ...
Page 10: ...Table of contents SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 10 Operating Instructions 06 2018 ...
Page 22: ...Description SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 22 Operating Instructions 06 2018 ...
Page 84: ...Operation 8 9 Faults SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 84 Operating Instructions 06 2018 ...
Page 112: ...Service and Support SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 112 Operating Instructions 06 2018 ...
Page 117: ...117 ...
Page 118: ...118 ...
Page 119: ...119 ...
Page 120: ...120 ...
Page 121: ...121 ...
Page 122: ...122 ...
Page 123: ...123 ...
Page 124: ...124 ...
Page 125: ...125 ...
Page 126: ...126 ...
Page 127: ...127 ...
Page 128: ...128 ...
Page 129: ...129 ...
Page 130: ...130 ...
Page 133: ...133 ...
Page 148: ...148 ...
Page 150: ...Additional documents SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 150 Operating Instructions 06 2018 ...
Page 154: ...Index SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 154 Operating Instructions 06 2018 ...
Page 155: ...AF Einbauerklärung Loher LDX U157 AJ EC Declaration of Conformity U161 ...