The machine design basically complies with the subsequent standards. Please refer to the EU
Declaration of Conformity for the versions of the harmonized standards referenced.
Table 3-1
Machine design
Feature
Standard
Rating and performance
IEC/EN 60034‑1
Degree of protection
IEC/EN 60034‑5
Cooling
IEC/EN 60034‑6
Type of construction
IEC/EN 60034‑7
Terminal markings and direction of rotation
IEC/EN 60034‑8
Noise emission
IEC/EN 60034‑9
Starting characteristics, rotating electrical machines
IEC/EN 60034‑12*
Vibration severity grades
IEC/EN 60034‑14
Vibration limits
DIN ISO 10816-3
* For machines in line operation only
See also
Quality documents (Page 115)
The following standards additionally apply for explosion-protected machines:
Table 3-2
Machine version with type of protection Ex db
Characteristic
Standard
Type of protection Ex db
GB 3836.1
GB 3836.2
Rating plate
The rating plate shows the identification data and the most important technical data. The data
on the rating plate and the contractual agreements define the limits of proper usage.
Line operation
The motor is supplied from the line system.
If you connect the machine to a converter, the machine can be damaged. Operate the machine
only on the electrical supply system.
Cooling
The cooling system is designed as a closed, internal cooling circuit. The heat lost from the
machine is dissipated to the ambient air via the machine's surface. A shaft-mounted fan moves
the cooling air in the primary circuit. Movement of the cooling air in the secondary circuit is
driven by a shaft-mounted fan.
Description
SIMOTICS HV C 1NB1402-2AA84-4CA0-Z
20
Operating Instructions 06/2018
Summary of Contents for 1NB1402-2AA84-4CA0-Z
Page 2: ...26 06 2018 15 34 V3 00 ...
Page 10: ...Table of contents SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 10 Operating Instructions 06 2018 ...
Page 22: ...Description SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 22 Operating Instructions 06 2018 ...
Page 84: ...Operation 8 9 Faults SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 84 Operating Instructions 06 2018 ...
Page 112: ...Service and Support SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 112 Operating Instructions 06 2018 ...
Page 117: ...117 ...
Page 118: ...118 ...
Page 119: ...119 ...
Page 120: ...120 ...
Page 121: ...121 ...
Page 122: ...122 ...
Page 123: ...123 ...
Page 124: ...124 ...
Page 125: ...125 ...
Page 126: ...126 ...
Page 127: ...127 ...
Page 128: ...128 ...
Page 129: ...129 ...
Page 130: ...130 ...
Page 133: ...133 ...
Page 148: ...148 ...
Page 150: ...Additional documents SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 150 Operating Instructions 06 2018 ...
Page 154: ...Index SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 154 Operating Instructions 06 2018 ...
Page 155: ...AF Einbauerklärung Loher LDX U157 AJ EC Declaration of Conformity U161 ...