![Siemens 1NB1402-2AA84-4CA0-Z Operating And Installation Instructions Download Page 82](http://html.mh-extra.com/html/siemens/1nb1402-2aa84-4ca0-z/1nb1402-2aa84-4ca0-z_operating-and-installation-instructions_378967082.webp)
8.9.3
Mechanical faults
Table 8-2
Mechanical faults
↓ Grinding noise
↓ Radial vibrations
↓ Axial vibrations
Possible causes of faults
Remedial measures
X
Rotating parts grind
Establish the cause and realign the parts.
X
Stator or coupling not balanced.
Disconnect the stator or coupling and rebalance.
If the machine has two shaft ends, and a transmission element is
only fitted to one end, secure the fitted key at the other end to prevent
it from being thrown out. If the rotor has balance type "H" (standard
type), the fitted key must be cut back to roughly half of its length.
X
Rotor out of true, shaft bent
Consult the manufacturing plant.
X
X
Poor alignment
Align the machine set; check the coupling.
(1)
X
Coupled machine not balanced
Rebalance the coupled machine.
X
Shocks from coupled machine
Investigate the coupled machine.
X
X
Uneven running of gear unit
Fix the gearing.
X
X
Resonance of the overall system com‐
prising motor and foundation
Stabilize the foundation following consultation.
X
X
Changes in foundation
Establish the cause of the changes and eliminate them if necessary;
realign the machine.
(1)
Take any changes into account when warming up the machine.
8.9.4
Roller bearing faults
Damage to roller bearings can be difficult to detect in some cases. If in doubt, replace the
bearing. Use other bearing designs only after consulting the manufacturer.
Table 8-3
Roller bearing faults
↓ Bearing overheats
↓ Bearing "whistles"
↓ Bearing "knocks"
Possible causes of faults
Remedial measures
X
High coupling pressure
Align the machine more accurately.
X
Belt tension too high
Reduce the drive belt tension.
X
Bearing contaminated
Clean or replace the bearing. Check the seals.
X
High ambient temperature
Use a suitable high-temperature grease.
X
X
Insufficient lubrication
Grease the bearings as instructed.
X
X
Bearing canted
Contact the Service Center.
X
X
Insufficient bearing play
Contact the Service Center.
X Excessive bearing play
Contact the Service Center.
X
X
Bearing corroded
Replace the bearing. Check the seals.
Operation
8.9 Faults
SIMOTICS HV C 1NB1402-2AA84-4CA0-Z
82
Operating Instructions 06/2018
Summary of Contents for 1NB1402-2AA84-4CA0-Z
Page 2: ...26 06 2018 15 34 V3 00 ...
Page 10: ...Table of contents SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 10 Operating Instructions 06 2018 ...
Page 22: ...Description SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 22 Operating Instructions 06 2018 ...
Page 84: ...Operation 8 9 Faults SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 84 Operating Instructions 06 2018 ...
Page 112: ...Service and Support SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 112 Operating Instructions 06 2018 ...
Page 117: ...117 ...
Page 118: ...118 ...
Page 119: ...119 ...
Page 120: ...120 ...
Page 121: ...121 ...
Page 122: ...122 ...
Page 123: ...123 ...
Page 124: ...124 ...
Page 125: ...125 ...
Page 126: ...126 ...
Page 127: ...127 ...
Page 128: ...128 ...
Page 129: ...129 ...
Page 130: ...130 ...
Page 133: ...133 ...
Page 148: ...148 ...
Page 150: ...Additional documents SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 150 Operating Instructions 06 2018 ...
Page 154: ...Index SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 154 Operating Instructions 06 2018 ...
Page 155: ...AF Einbauerklärung Loher LDX U157 AJ EC Declaration of Conformity U161 ...