9.4.8
Seal the motor
Extreme caution and attention to cleanliness are vital to installation.
● Clean all bare joints between parts such as housings, bearing shields and bearing bushes
etc., and remove old sealant material.
● Smear bare joints between parts with non-hardening, permanently flexible sealant, such
as "Hylomar M". Follow the manufacturer's application and safety instructions when doing
this.
● Check all sealing elements, such as those on the terminal boxes, for elasticity, aging or
damage, and renew them if they are no longer effective.
Replace the seals if necessary with original parts or with tested sealing elements. The seals
must be fully bonded to the motor and the air intake housing. It is impermissible to have gaps
and holes where seals make contact.
● Surfaces whose mating faces are sealed using liquid sealant can be resealed by applying
the original liquid sealant (Hylomar M).
● Surfaces whose mating faces are sealed using sealings that adhere to one side only can
be resealed with the original sealing using the original adhesives (Loctite).
If you are installing covers that are sealed with liquid gasket, proceed as follows to maintain
the IP degree of protection of the machine before closing it again:
1. Use only approved liquid sealants.
2. Clean the sealing surfaces according to the technical data sheet of the liquid sealant. The
sealing surfaces must be clean and dry before reassembly.
3. Apply the liquid gasket as a continuous bead with a diameter of approx. 3 mm.
4. Assemble the components after the solvent has had a chance to vaporize, while still
assembling within the specified assembly time.
5. Retighten the fixing screws of the cover after the liquid sealant has set.
Note
If you have any questions, contact the Service Center.
See also
Service and Support (Page 111)
Maintenance
9.4 Corrective Maintenance
SIMOTICS HV C 1NB1402-2AA84-4CA0-Z
100
Operating Instructions 06/2018
Summary of Contents for 1NB1402-2AA84-4CA0-Z
Page 2: ...26 06 2018 15 34 V3 00 ...
Page 10: ...Table of contents SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 10 Operating Instructions 06 2018 ...
Page 22: ...Description SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 22 Operating Instructions 06 2018 ...
Page 84: ...Operation 8 9 Faults SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 84 Operating Instructions 06 2018 ...
Page 112: ...Service and Support SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 112 Operating Instructions 06 2018 ...
Page 117: ...117 ...
Page 118: ...118 ...
Page 119: ...119 ...
Page 120: ...120 ...
Page 121: ...121 ...
Page 122: ...122 ...
Page 123: ...123 ...
Page 124: ...124 ...
Page 125: ...125 ...
Page 126: ...126 ...
Page 127: ...127 ...
Page 128: ...128 ...
Page 129: ...129 ...
Page 130: ...130 ...
Page 133: ...133 ...
Page 148: ...148 ...
Page 150: ...Additional documents SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 150 Operating Instructions 06 2018 ...
Page 154: ...Index SIMOTICS HV C 1NB1402 2AA84 4CA0 Z 154 Operating Instructions 06 2018 ...
Page 155: ...AF Einbauerklärung Loher LDX U157 AJ EC Declaration of Conformity U161 ...