![Siemens Healthcare Clinitek Status Connect System Operator'S Manual Download Page 39](http://html.mh-extra.com/html/siemens-healthcare/clinitek-status-connect-system/clinitek-status-connect-system_operators-manual_1266125039.webp)
Clinitek Status Connect System
39
Operator’s Guide
5 Data Management
This section describes data storage and management on the instrument.
Clinitek analyzers may contain up to 950 patient test and 200 QC test
results and up to 700 authorized operators.
Clinitek Status analyzers may contain up to 200 patient test and 50 QC test
results and 20 authorized operators.
NOTE:
If the LIS sends the Operators List to the system, Operator Names are
not retained if the system loses power. The LIS must resend the list.
Managing Patient and System Information
This section describes how to recall or delete patient or QC records. You can
recall all patient data or QC tests or search records by ID or date. You can
also delete all patient and QC records stored on the instrument.
Recalling Patient or QC Data
To recall patient or QC records, perform the following steps:
1. At the
Select Ready
screen, select
Recall Results
.
The
Recall Options
screen displays.
2. Use the arrow keys to select
Recall Patient Tests or QC Tests
.
3. Select
Select
.
The
Recall Results
screen displays.
4. To search patient tests, select
Patient tests
.
To search QC tests, select
QC tests
.
5. Select
Next
.
The
Recall Results
screen displays.
6. There are 3 ways to search:
•
To search by patient name or ID, select
Search by name or ID
. Go
to Step 7.
•
To search by date, select
Search by date
. Go to Step 9.
•
To retrieve all the data, select
View all results
. Go to Step 11.
7. Enter patient name or ID.
Use the alpha keyboard to enter text.
To enter numeric text, select
123
.
8. Select
Enter
. Go to Step 11.
9. Use the arrow keys to indicate the date range.
10. Select
Search
.
The
Recall Results-Search Results
screen displays.
Summary of Contents for Clinitek Status Connect System
Page 1: ...Clinitek Status Connect System Operator s Guide For US Only 10490852 2009 12 135055 Rev A ...
Page 6: ...Clinitek Status Connect System 6 Operator s Guide ...
Page 14: ...Clinitek Status Connect System 14 Operator s Guide ...
Page 24: ...Clinitek Status Connect System 24 Operator s Guide ...
Page 36: ...Clinitek Status Connect System 36 Operator s Guide ...
Page 38: ...Clinitek Status Connect System 38 Operator s Guide ...
Page 54: ...Clinitek Status Connect System 54 Operator s Guide ...
Page 56: ...Addresses www siemens com diagnostics Clinitek Status Connect System 56 Operator s Guide ...
Page 58: ...Clinitek Status Connect System 58 Operator s Guide ...
Page 64: ...Clinitek Status Connect System 64 Operator s Guide ...
Page 68: ...Clinitek Status Connect System 68 Operator s Guide ...
Page 72: ...Clinitek Status Connect System 72 Operator s Guide ...