200
(7.87)
160
(6.3)
120
(4.72)
80
(3.15)
40
(1.57)
0
Min. distance from object to background in mm (inch)
0
1,000
(39.37)
2,000
(78.74)
3,000
(119.11)
Distance in mm (inch)
1
2
3
5
4
Figura: H-1 - Small teach and analog 6%/90%
1
6%/90% AVG1
2
6%/90% AVG4
3
6%/90% AVG16
4
6%/90% AVG64
5
6%/90% AVG256
180
(7.09)
160
(6.03)
120
(4.72)
80
(3.15)
40
(1.57)
140
(5.51)
100
(3.94)
60
(2.36)
20
(0.79)
0
Min. distance from object to background in mm (inch)
0
1,000
(39.37)
2,000
(78.74)
3,000
(118.11)
Distance in mm (inch)
1
2
3
4
5
Figura: H-2 - Small teach and analog 90%/90%
1
90%/90% AVG1
2
90%/90% AVG4
3
90%/90% AVG16
4
90%/90% AVG64
5
90%/90% AVG256
90
(3.54)
80
(3.15)
60
(2.36)
40
(1.57)
20
(0.79)
70
(2.76)
50
(1.97)
30
(1.18)
10
(0.39)
0
Repeatability (1
σ
) in mm (inch)
0
1,000
(39.37)
2,000
(78.74)
3,000
(118.11)
Distance in mm (inch)
1
2
3
4
5
Figura: H-3 - Small Analog 6%
1
6% AVG1
2
6% AVG4
3
6% AVG16
4
6% AVG64
5
6% AVG256
35
(1.38)
30
(1.18)
25
(0.98)
20
(0.79)
15
(0.59)
10
(0.39)
5
(0.2)
0
Repeatability (1
σ
) in mm (inch)
0
1,000
(39.37)
2,000
(78.37)
3,000
(118.11)
Distance in mm (inch)
1
5
3
2
4
Figura: H-4 - Small Analog 90%
1
90% AVG1
2
90% AVG4
3
90% AVG16
4
90% AVG64
5
90% AVG256
35.2
Montaggio
Montare il sensore su una staffa di fissaggio adatta (vedi il programma per accessori
SICK).
Rispettare il momento torcente massimo consentito del sensore di 0.8Nm.
Rispettare la direzione preferenziale dell'oggetto in relazione al sensore [cfr. F].
35
MESSA IN FUNZIONE
62
8020032.17U4 | SICK
Subject to change without notice