![SICK WI180C-IOA00 Operating Instructions Manual Download Page 54](http://html1.mh-extra.com/html/sick/wi180c-ioa00/wi180c-ioa00_operating-instructions-manual_1264708054.webp)
Index
Function
WLL180T
KTL180
OD1 / AO
D1
OL1 / AOD
1
AOD1
Acc-
ess
Data type
Content/meaning
129
Product series, ampli‐
fier
-
-
x
x
x
rw
UInt 16
0x1,503: AOD1
130
Switching point near
-
-
x
-
-
rw
Int 16
OD1 15 mm: -7,499 … 7,499 (default:
-1,000)
OD1 35 mm: -2,249 … 2,249 (default:
-300)
OD1 100 mm: -7,499 … 7,499 (default:
-1,000)
131
Switching point far
-
-
x
-
-
rw
Int 16
OD1 15 mm: -7,499 … 7,499 (default:
1,000)
OD1 35 mm: -2,249 … 2,249 (default:
300)
OD1 100 mm: -7,499 … 7,499 (default:
1,000)
132
Background ObSB
-
-
x
-
-
rw
Int 16
OD1 15 mm: -7,499 … 7,499 (default: 0)
OD1 35 mm: -2,249 … 2,249 (default: 0)
OD1 100 mm: -7,499 … 7,499 (default:
0)
133
Tolerance ObSB
-
-
x
-
-
rw
Int 16
OD1 15 mm: 0 … 7,499 (default: 1,000)
OD1 35 mm: 0 … 2,249 (default: 300)
OD1 100 mm: 0 … 7,499 (default: 1,000)
134
Moving average
-
-
x
-
-
rw
UInt 16
0: over one value
1: 8 values
2: 64 values
3: 512 values
Moving average
-
-
-
x
-
rw
UInt 16
1 … 128 (scanning points)
135
Teach-in mode
-
-
x
-
-
rw
UInt 16
0: 2-point
1: 1-point
2: ObSB
Measurement type
-
-
-
x
-
rw
UInt 16
0: Positive edge
1: Negative edge
2: Width
136
Sampling rate
-
-
x
-
-
rw
UInt 16
0: 500 µs
1: 1 ms
2: 2 ms
3: 4 ms
4: Auto
Sampling rate
-
-
-
x
-
rw
UInt 16
0: 500 µs
137
Key lock
-
-
x
-
-
rw
UInt 16
0: Unlocked
1: Locked
138
Switching behavior
-
-
x
-
-
rw
UInt 16
0: Light on
1: Dark on
139
Calibration, near dis‐
tance
-
-
x
-
-
rw
Int 16
OD1 15 mm: -7,499 … 7,499 (default:
-5,000)
OD1 35 mm: -2,249 … 2,249 (default:
-1,500)
OD1 100 mm: -7,499 … 7,499 (default:
-5,000)
140
Calibration, far dis‐
tance
-
-
x
-
-
rw
Int 16
OD1 15 mm: -7,499 … 7,499 (default:
5,000)
OD1 35 mm: -2,249 … 2,249 (default:
1,500)
OD1 100 mm: -7,499 … 7,499 (default:
5,000)
141
Error behavior
-
-
x
-
-
rw
UInt 16
0: Clamp
1: Hold
142
Clamp holding time
-
-
x
-
-
rw
UInt 16
0 … 9,999 (default: 0)
143
Direction of measure‐
ment
-
-
-
x
-
rw
UInt 16
0: From top to bottom
1: From bottom to top
144
Zeroing value
-
-
x
-
-
rw
Int 16
OD1 15 mm: -7,499 … 7,499 (default: 0)
OD1 35 mm: -2,249 … 2,249 (default: 0)
OD1 100 mm: -7,499 … 7,499 (default:
0)
OL1: -9,999 … 5,000 (default: 0)
11
ANNEX
54
O P E R A T I N G I N S T R U C T I O N S | WI180C-IOA00
8025143/2020-01-23 | SICK
Subject to change without notice