32770
Process data variables
The sensor outputs analog values as process data elements.
11.7.5.2
Module data
Table 36: System-specific ISDUs – Module communication / data
ISDU
Name
Data type
Data Stor‐
age
Length
Access
Default
value
Value/range
Index
Sub-
index
DEC
HEX
262
106
-
Module communication tun‐
nel
Record
-
3 bytes
rw
-
-
1
Module Number
8 bits (offset:
16 bits)
1
1 = Module 1
2 = Module 2
3 = Module 3
4 = Module 4
5 = Module 5
6 = Module 6
7 = Module 7
8 = Module 8
9 = Module 9
10 = Module 10
11 = Module 11
12 = Module 12
13 = Module 13
14 = Module 14
15 = Module 15
16 = Module 16
2
Module Address
8 bits (offset: 8 bits)
0
3
Data Length
8 bits (offset: 0 bits)
0
0 ... 32
263
107
Module data
Record
35 bytes
1
Data
32 bytes (offset:
24 bits)
2
Module Number Readback
8 bits (offset:
16 bits)
3
Module Address Readback
8 bits (offset: 8 bits)
4
Data Length Readback
8 bits (offset: 0 bits)
Unsigned Integer32 [16]
269
10D
Module process data
Array
64 bytes
ro
8
0 ... 16
270
10E
Module count
UInt
8 bits
The “Module data” function can be used to access the parameters of each module connected to the WI180C-
IOA00. The desired addressing is specified in function 262 “module communication tunnel”:
•
Subindex 1 - Desired module for parameter communication (1 ... 16)
•
Subindex 2 - Address of the desired parameter (see below)
•
Subindex 3 - Desired data length in bytes (0 ... 32)
After writing function 262, function 263 “Module data” can be used to read the desired parameter (for read
access) or, after setting the data in subindex 1, to write to the parameter (for write access).
In the case of read access, the associated address data can be verified via subindexes 2, 3, 4 (see function 262
for coding). These subindexes are meaningless for write access.
Besides the parameter data of the modules, function 269 “Module process data” can also be used to read the
currently valid process data of a specific module. This makes it possible to access each process datum regardless
of the setting in index 67 or 120.
NOTE
Access to the functions 262, 263, 269 is via ISDU communication and is therefore slower than communication via
the process data channel.
Function 270 “Module count” returns the current number of connected modules.
11
ANNEX
50
O P E R A T I N G I N S T R U C T I O N S | WI180C-IOA00
8025143/2020-01-23 | SICK