Protective fields
Default:
No protective fields are configured, i.e., all field points, segments of a
protective field are deleted (no entries).
For all fields in all field sets, the reference contour (Contour as Reference) is
"deactivated".
Deleting the field points means that the corresponding outputs for signaling protective
field infringements are active (active low) until they are actively changed.
When the field points are deleted, the field editor will not display any protective fields!
5.4.6
Passwords
Software access to the TiM361S is protected by various passwords. After configuring
the device successfully, the respective password must be changed so that it can fulfill
its protective function.
User level
Password factory settings
Maintenance
sicksafe98
Authorized client
sicksafe99
The "Maintenance" user level enables parameter changes to be saved, among other
things.
The "Authorized client" user level allows for general sensor configuration.
5.5
Editing fields
Fields can be created and edited on the "Analysis fields" page (below the "Parameters"
node).
Before editing a field, first select the desired field set itself and the desired field within
the field set.
Field set no. 1 and Field no. 1 are preset.
Different from all other parameters, changes to fields (adding, moving or removing
individual field points or entire fields) are not transferred to the device until the
"Download all fields to device" button is clicked.