3
Product description
3.1
Device view
1
2
3
4
5
6
7
8
9
ß
à
á
â
1
X1 – IO LINK MASTER: connections for IO-Link and/or GPIO
2
X2 – POWER: connections for the device voltage supply
3
X3 – OUTPUT: connections for digital switching outputs
4
X4 – INPUT A: connections for digital switching inputs A
5
X5 – INPUT B: connections for digital switching inputs B
6
X6 – SERIAL A: serial connections A
7
X7 – SERIAL B: serial connections B
8
X8 – CAN: connections for SICK CAN sensor network with termination resistor which can
be activated
9
X9 to X12 – ETHERNET: 4 Ethernet connections
ß
X13 to X14 – FIELDBUS: 2 connections for Ethernet-based fieldbuses
à
Device status indicators
á
Servicing panel: function button, function selector switch, USB connection (for configura‐
tion/diagnostics)
â
Status indicators for Ethernet and fieldbus connections
3.2
Functionality
The Sensor Integration Machine – part of the SICK AppSpace eco-system – is opening
up new possibilities for customized application solutions.
Data from SICK sensors such as 1D/2D code sensors and VMS4xx/5xx for detecting
object geometry can be imported, evaluated, archived, and transmitted. In order to do
this, the sensors can be connected to the SIM via the CAN bus. Ethernet-based fieldbus
interfaces ensure rapid communication with controls.
PRODUCT DESCRIPTION
3
8020764/1FTA/2022-05-02 | SICK
O P E R A T I N G I N S T R U C T I O N S | SIM2000ST
11