Command
Description
Visibility
Access
TestPayloadFormatMode
This feature allows setting a device in test mode and to
output a specific payload formatting for validation of
data streaming.
Guru
R
TestPayloadType
This feature selects the payload type the device will use
for streaming when the TestPayloadFormatMode fea‐
ture is active.
Guru
R
7.13.12
Transport layer control
Normally, the user must not edit these features. Changing them can cause errors.
Table 33: Transport layer control standard SFNC parameters
Parameter
Type
Description
Visibility
Access
PayloadSize
int
Provides the number of bytes transferred for each
image or chunk on the stream channel.
Expert
R
7.13.12.1
GigEVision
Normally, the user do not edit these parameters. Changing them can cause errors.
Table 34: GigEVision control standard SFNC parameters
Parameter
Type
Description
Visibility
Access
GevMCPHostPort
int
Controls the port to which the device must send mes‐
sages.
Guru
R
GevMCDA
int
Controls the destination IP address for the message
channel.
Guru
R
GevMCTT
int
Provides the transmission timeout value in millisec‐
onds.
Guru
R
GevMCRC
int
Controls the number of retransmissions allowed when
a message channel message times out.
Guru
R
GevMC SP
int
Indicates the source port for the message channel.
Guru
R
GevSCPHostPort
int
Controls the port of the selected channel to which a
GVSP transmitter must send data stream or the port
fromwhich a GVSP receiver may receive data stream.
Guru
R
GevSCPSPacketSize
int
Specifies the stream packet size, in bytes, to send on
the selected channel for a GVSPtransmitter (set by
negotiation between the device and PC during connec‐
tion) or specifies the maximum packet size supported
by a GVSP receiver.
Expert
R
GevSCPD
int
Controls the delay (in GEV timestamp counter unit) to
insert between each packet for this stream channel.
This feature can be used as a crude flow-control mech‐
anism if the application or the network infrastructure
cannot keep up with the packets coming from the
device.
Expert
RW
GevSCDA
int
Controls the destination IP address of the selected
stream channel to which a GVSP transmitter must send
data stream or the destination IP address from which a
GVSP receiver may receive data stream.
Guru
R
GevSCSP
int
Indicates the source port of the stream channel.
Guru
R
MultiPartSupport
bool
Manual Enable/Disable of multipart-configuration bit
(25) in SCCFGx register for testing.
Guru
RW
GevMACAddress
int
MAC address of the logical link.
Expert
R
GevCurrentIPConfigurationPersis‐
tent IP
bool
Controls whether the PersistentIP configuration scheme
is activated on the given logical link.
Expert
R
7
CONFIGURATION
44
O P E R A T I N G I N S T R U C T I O N S | Ranger3
8020774/14IM/2019-07 | SICK
Subject to change without notice