Example: x = 1,000 mm, y = 25 mm. That is, the background is suppressed at a distance
of > 25 mm behind the object.
0
5
(0.2)
10
(0.39)
15
(0.59)
20
(0.79)
25
(0.98)
30
(1.18)
35
(1.38)
40
(1.57)
0
1
6%/90%
2
6%/90%
90%/90%
5
4
90%/90%
3
6%/90%
6
90%/90%
Min. distance from object to background in mm (inch)
1,000
(39.37)
2,000
(78.74)
3,000
(118.11)
4,000
(157.48)
Distance in mm (inch)
1) -Bxx3x: 6 % / 90 %
2) -Bxx3x: 90 % / 90 %
3) -Bxx6x: 6 % / 90 %
4) -Bxx6x: 90 % / 90 %
5) -Bxx4x: 6 % / 90 %
6) -Bxx4x: 90 % / 90 %
Figure: H-1
0
4
5
6
90%/90%
90%/90%
90%/90%
1
6%/90%
2
3
6%/90%
6%/90%
30
(1.18)
20
(0.79)
10
(0.39)
50
(1.97)
40
(1.57)
500
(19.69)
1,000
(39.37)
1,500
(59.06)
2,000
(78.74)
Min. distance from object to background in mm (inch)
Distance in mm (inch)
1) -Bxx1x: 6 % / 90 %
2) -Bxx1x: 90 % / 90 %
3) -Bxx5x: 6 % / 90 %
4) -Bxx5x: 90 % / 90 %
5) -Bxx2x: 6 % / 90 %
6) -Bxx2x: 90 % / 90 %
Figure: H-2
2
Mount the sensor using a suitable mounting bracket (see the SICK range of accessories).
Note the sensor's maximum permissible tightening torque of 0.8 Nm.
Note the preferred direction of the object relative to the sensor [see E].
3
Operation in standard I/O mode:
The sensors must be connected in a voltage-free state (U
v
= 0 V). The information in the
graphics [B] must be observed, depending on the connection type:
–
Male connector connection: pin assignment
–
Cable: core color
Figure 1: B
Only apply voltage/switch on the power supply (U
v
> 0 V) once all electrical connections
have been established. The green LED indicator lights up on the sensor.
Operation in IO-Link mode: Connect the device to a suitable IO-Link master and integrate in
the master or control via IODD/function block. The green LED indicator flashes on the sen‐
sor. IODD and function block are available to download from www.sick.com under the order
number.
Explanations of the connection diagram (Graphic B):
Teach-in = external teach-in (ET) (see Adjustment)
TI / Test = test input (see Additional functions)
COMMISSIONING
3
8018110.ZM26 | SICK
Subject to change without notice
5