Commissioning and configuration
52
© SICK AG · Germany · All rights reserved · Subject to change without notice
8013889/ZML0/2017-06-09
Operating Instructions
NAV350 Laser positioning sensor
Chapter
6
6.3.1
Connect the data interfaces
Connect the PC to the NAV350 using the Ethernet cable (see
fig. 28 on page 48
)
or
Connect the PC (serial interface) to the NAV350 (see
fig. 29 on page 48
)
6.3.2
Starting SOPAS ET and opening the scan assistant
1. Start SOPAS ET.
By default SOPAS ET opens the program window with the English user interface.
2. To change the language setting, in the start dialog box click C
ANCEL
and using the menu
T
OOLS
, O
PTIONS
change the language for the user interface to G
ERMAN
.
3. If the language setting has been modified, quit SOPAS ET and re-start.
4. In the dialog box, choose the option C
REATE
NEW
PROJECT
and confirm with OK.
5. In the main window in S
CAN
A
SSISTANT
click the C
ONFIGURATION
button.
The S
CAN
A
SSISTANT
dialog box appears.
6.3.3
Configuring the serial connection
1. In the S
CAN
A
SSISTANT
dialog box,
under S
ERIAL
CONNECTION
, S
TANDARD
P
ROTOCOL
, activate
the A
CTIVATE
S
ERIAL
COMMUNICATION
checkbox.
2. Click A
DVANCED
... button.
3. In C
OLA
DIALECT
choose the ASCII option.
4. Choose following P
ORT
SETTINGS
: 8 data bits, even parity, 1 stop bit.
5. Confirm the settings with OK.
The A
DVANCED
SCAN
SETTINGS
dialog box is closed.
6. Confirm the settings in the S
CAN
A
SSISTANT
dialog box with OK.
The S
CAN
A
SSISTANT
dialog box is closed.
6.3.4
Configuring the Ethernet connection
The factory setting for the Ethernet interface of the NAV350 is as follows:
– IP address: 192.168.1.10
– subnet mask: 255.255.255.0
– TCP/ IP port for SOPAS ET: 2111
Configuring with fixed IP address
Important
Deactivate all programs on your PC/notebook that access Ethernet or TCP/IP.
1. From the START MENU, click CONTROL PANEL and choose NETWORK CONNECTIONS.
2. Right-click the LOCAL AREA CONNECTION icon, and then choose PROPERTIES.
3. On the GENERAL tab, highlight INTERNET PROTOCOL (TCP/IP), and then click PROPER-
TIES
4. Select USE THE FOLLOWING IP ADDRESS, and enter the following IP address:
192.168.1. x (e.g. 1)
5. Confirm with OK