6.2
Connection overview
NOTE
The USB connection may only be used temporarily and only for configuration and
diagnostics.
6.2.1
microScan3 Pro I/O
Table 6: System connector and connectors: microScan3 Pro I/O
Safety laser scanner
Suitable system plug
Plug connector
microScan3 Pro I/O
XD1
XF1
XF2
XG1
XG2
XG4
XG3
MICSX-CAAAMDMD1 (part number: 2115434)
•
XD1: Voltage supply,
•
XF1, XF2: 2 × Ethernet for EFI-
pro, data output, configuration
and diagnostics,
•
XG1: Local inputs and outputs
1,
•
XG2, XG3: Dynamic control
inputs,
•
XG4: Local inputs and outputs
2,
•
Alternate FE port,
6.3
Pin assignment
You will find the pin assignment for the individual plug connectors in the following.
6.3.1
Voltage supply (XD1)
Voltage supply is supplied via a 4-pin, A-coding M12 male connector on the device side.
2
1
4
3
Figure 56: Pin assignment of the voltage supply (male connector, M12, 4-pin, A-coded)
Table 7: Pin assignment of the voltage supply
PIN
Designation Function
Wire color
1)
1
+24 V DC
Supply voltage 24 V DC
Brown
2
nc
Not connected
White
3
0 V DC
Supply voltage 0 V DC
2)
Blue
4
FE
Functional earth/shield
Black
1)
Applies to the connecting cables recommended as accessories.
2)
All used 0 V connections of the device must be connected in the control cabinet using a low-impedance
and star-point connection with 0 V DC of the power supply unit.
6.3.2
Alternative FE connection
Figure 57: Alternative FE connection
Screw connection of the alternative FE connection
•
Screw: M5 × 12
•
Tightening torque: 3.5 Nm to 5.0 Nm
6
ELECTRICAL INSTALLATION
92
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
8025424/1ELL/2022-01-21 | SICK
Subject to change without notice