Name
Use
Data type
Definition
Values
Safety implica‐
tion
SetMonitoringCaseNoTable2
USINT
Monitoring case num‐
ber (Monitoring case
table 2)
Activates the monitor‐
ing case with the cor‐
responding number in
monitoring case table
02.
0 = invalid
Safety-relevant
parameter
1 … 254 = num‐
ber of the moni‐
toring case
SetMonitoringCaseNoTable3
USINT
Monitoring case num‐
ber (Monitoring case
table 3)
Activates the monitor‐
ing case with the
respective number in
monitoring case table
03.
0 = invalid
Safety-relevant
parameter
1 … 254 = num‐
ber of the moni‐
toring case
SetMonitoringCaseNoTable4
USINT
Monitoring case num‐
ber (Monitoring case
table 4)
Activates the monitor‐
ing case with the cor‐
responding number in
monitoring case table
04.
0 = invalid
Safety-relevant
parameter
1 … 254 = num‐
ber of the moni‐
toring case
Speed1
INT
Speed at dynamic con‐
trol input 1
-32000 ...
+32000 = speed
in mm/s
Safety-relevant
parameter
Speed1Valid
BOOL
Speed1 valid
0 = Invalid speed Safety-relevant
parameter
1 = speed valid
Speed2
INT
Speed at dynamic con‐
trol input 2
-32000 ...
+32000 = speed
in mm/s
Safety-relevant
parameter
Speed2Valid
BOOL
Speed2 valid
0 = Invalid speed Safety-relevant
parameter
1 = speed valid
StopAlarmDetection
Additional func‐
tion
BOOL
Stop Event history
0 = event history
active, field inter‐
ruptions are
recorded
Parameter with‐
out safety impli‐
cation
1 = event history
not active, field
interruptions are
not recorded,
existing record‐
ings are retained
TriggerDeviceRebootWithNet‐
work
Additional func‐
tion
BOOL
Restart device com‐
pletely
Restarts the device and
the network stack. The
internal switch function
is interrupted.
0 = no restart
Parameter with
implication for
the safety func‐
tion
0-1-0 = device
restart
(duration of sta‐
tus 1 ≥ 120 ms)
1 = ignored
TECHNICAL DATA
13
8025424/1ELL/2022-01-21 | SICK
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
195