S
Figure 32: Stationary application in vertical operation for access protection
Important information
DANGER
Hazard due to lack of effectiveness of the protective device
Persons and parts of the body to be protected may not be recognized in case of
non-observance.
b
Use a resolution of 200
mm or finer. Otherwise, protection will not be ensured
during access protection.
b
Use double sampling during access protection. Under certain circumstances, a
person could pass through the protective field without being detected when using
higher multiple sampling.
b
Use the contour of the environment as a reference to protect the protective device
from inadvertent adjustment or tampering (
see "Reference contour monitoring",
).
DANGER
Hazard due to lack of effectiveness of the protective device
If there is a retroreflector in the protective field level (distance of the retroreflector from
protective field ≤ 6 m), it may not be possible detect people and parts of the body that
are to be protected, or it may not be possible to detect them on time.
b
Avoid retroreflectors in the protective field level if possible.
b
With retroreflectors at the protective field level: Increase overrun of the protective
field over the opening to be protected by supplement Z
R
= 350 mm.
PROJECT PLANNING
4
8025424/1ELL/2022-01-21 | SICK
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
45
Subject to change without notice