5
4
2
3
7
6
8
1
Figure 60: Pin assignment of dynamic control input (female connector, M12, 8-pin, A-coded)
Table 10: Pin assignment for dynamic control input
PIN
Designation Function
1
nc
Not connected
2
Inc 0°
Incremental encoder signal (0°)
3
nc
Not connected
4
Inc 90°
Incremental encoder signal (90°)
5
nc
Not connected
6
nc
Not connected
7
0 V Inc
Supply voltage for incremental encoder (0 V DC)
8
24 V DC Inc
Supply voltage for incremental encoder (+24 V DC)
6.3.6
Local inputs and outputs 2 (XG4)
The local inputs and outputs are connected on the device side via 17-pin, A-coded M12
female connectors.
If both 17-pin connections are used, both 17-pin cables must be clearly marked to
prevent confusion when replacing the device.
1
2
6
7
14
12
3
4
5
8
9
10
11
13
15
17
16
Figure 61: Pin assignment of inputs and outputs 2 (female connector, M12, 17-pin, A-coded)
Table 11: Pin assignment for local inputs and outputs 2
PIN
Designation Function
1
2
3
4
5
nc
Not connected
6
nc
Not connected
7
nc
Not connected
8
nc
Not connected
9
Uni-I 11
Universal input 11, configurable:
•
•
Universal input: sleep mode, restarting the device, pausing
event recording
10
Uni-I 12
Universal input 12, configurable:
•
•
Universal input: sleep mode, restarting the device, pausing
event recording
ELECTRICAL INSTALLATION
6
8025424/1ELL/2022-01-21 | SICK
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
95
Subject to change without notice