OPERATION
7
89
8020065-ZLP4/2017-08-10|SICK
Subject to change without notice
O P E R A T I N G I N S T R U C T I O N S | Master Data Analyzer
Repeat measurement in the operating mode without bar code scanning
Before repeating a measurement without bar code scanning, the object has to be
removed from the glass panel and repositioned again. This creates a new measurement
data set.
1. Remove the object from the glass panel.
2. Place the object correctly in the measurement field on the glass panel.
3. Wait until a stable weight is displayed.
4. Move the measurement gantry over the object.
Once the volume has been measured, all measured values appear on the display and
are transmitted by the MSC800 controller to the customer system via the defined
interface.
You will receive a message if you have failed to remove the object from the glass panel
before the repeat measurement.
You will also receive this message if you have accidentally measured the same object
twice.
7.6.2
Volume measurement without bar code (only for operating mode with bar code scanning)
In the operating mode with bar code scanning, you may accidentally measure the volume
before scanning the bar code. In this case, the following error message appears:
Note