16
7 Dismount
LFV200 • IO-Link
41222-01-170809
Error
Reason
Rectification
Green sig-
nal lamp off
Voltage
supply inter-
rupted.
Check the voltage supply
and the cable connection
Electronics
defective
Exchange the instrument
or send it in for repair
Red signal
lamp lights
(switching
output high-
impedance)
Error with
the elec-
trical
connection
Connect the instrument
according to the wiring
plan
Shortcircuit
or overload
Check the electrical con-
nection
Red sig-
nal lamp
flashes
(switching
output high-
impedance)
Vibrating
frequency
out of speci-
fication
Check the vibrating ele-
ment on buildup and
remove it
Buildup on
the vibrating
element
Check the vibrating ele-
ment and the sensor if
there is buildup and re-
move it
Vibrating
element da-
maged
Check if the vibrating
element is damage or ext-
remely corroded
7 Dismount
7.1 Dismounting steps
Warning:
Before dismounting, be aware of dan-
gerous process conditions such as e.g.
pressure in the vessel, high temperatu-
res, corrosive or toxic products etc.
Take note of chapters "
Mounting
" and "
Connec-
ting to power supply
" and carry out the listed
steps in reverse order.
7.2 Disposal
The instrument consists of materials which can
be recycled by specialised recycling companies.
We use recyclable materials and have designed
the electronics to be easily separable.
WEEE directive 2002/96/EG
This instrument is not subject to the WEEE
directive 2002/96/EG and the respective nati-
onal laws. Pass the instrument directly on to a
specialised recycling company and do not use
the municipal collecting points. These may be
used only for privately used products according
to the WEEE directive.
Correct disposal avoids negative effects on
humans and the environment and ensures
recycling of useful raw materials.
Materials: see chapter "
Technical data
"
If you have no way to dispose of the old instru-
ment properly, please contact us concerning
return and disposal.