Only mount the device using the threaded mounting holes provided or the movable
sliding nuts.
•
Mount the device in a shock and vibration insulated manner.
•
Make sure the device has a clear view of the objects to be scanned.
Auxiliary equipment required
■
Mounting system with sufficient load-bearing capacity and suitable dimensions
■
4 or 2 M5 screws for mounting the device on a mounting system supplied by the
customer
■
Tool and tape measure
The screw length depends on the mounting base (wall thickness of the bracket). When
using an optional SICK mounting system, the screws for mounting the device are
included with delivery.
5.3.2
Mounting the device
The device is mounted using threaded mounting holes (M5) or sliding nuts.
The threaded mounting holes are located on the rear of the device.
The sliding nuts can each be inserted into a slot on the side of the housing.
SICK offers prefabricated brackets which are optimally suited for mounting the device
in a wide range of applications (
).
User-supplied brackets
A user-supplied bracket must meet the following requirements:
•
Alignment of the device in the x and y axes can be adjusted
•
The mounting device must be able to bear the weight of the device and connecting
cables free of vibrations
•
In mounting situations with strong vibrations, shock mounts may need to be
provided
•
Mounting options must be available for the 4 threaded mounting holes or the two
sliding nuts
5.4
Mount the optics
NOTE
This mounting step is only required if the optional optics accessory has been included
in the order for a programmable vision sensor of the InspectorP6xx Flex product family.
This does not apply for the Dynamic Focus type.
5.4.1
Mounting the lens and illumination
NOTICE
Possible impairment of image quality!
Dust and fingerprints on optical boundary surfaces can reduce image quality and may
also affect the analysis performance of the device.
■
When mounting the optics accessories, always ensure that the environment is free
of dust.
■
Do not touch the image sensor (CMOS) in the light inlet opening of the sensor or
the glass lenses at either end of the lens unit.
MOUNTING
5
8019943/1EJ6/2022-02 | SICK
O P E R A T I N G I N S T R U C T I O N S | InspectorP64x/65x
21