13.4.4
Wiring serial host interface RS-232 of the device in the CDM420-0006
Device = InspectorP64x = V2D64xP-xxxxAx
Device = InspectorP65x = V2D65xP-xxxxAx
Device
1
CDM420-0006
Host
5
.
.
.
TxD
RxD
RxD
TxD
GND
GND
GND
12
1
9
7
6
34
T
‒
/TxD
35
R
‒
/RxD
36
GND
6
Shield
RS-232
RS-232
ON
OFF
S2 : RS 485
ON
OFF
S3: Term 422
S2
OFF
ON
2
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
1
10
15
6
11
5
4
3
Figure 21: Wiring data interface RS-232 of the device in connection module CDM420-0006.
1
Device
2
Adapter cable (male connector, D-Sub-HD, 15-pin / female connector, M12, 17-pin, A-coded)
3
Connection module: female connector, D-Sub-HD, 15-pin
4
Device: male connector, M12, 17-pin, A-coded
NOTE
Activate the RS-232 data interface in the device with the SICK AppStudio development
environment.
13.4.5
Wiring serial host interface RS-422 of the device in the CDM420-0006
Device = InspectorP64x = V2D64xP-xxxxAx
Device = InspectorP65x = V2D65xP-xxxxAx
13
ANNEX
62
O P E R A T I N G I N S T R U C T I O N S | InspectorP64x/65x
8019943/1EJ6/2022-02 | SICK
Subject to change without notice