Table 8: Data transmission rates and recommended maximum lengths of cable
Interface
Data transmission rate
Distance to the target computer
(host)
NOTICE
Risk of damage to the internal interface modules!
If the serial data interfaces are wired incorrectly, then electronic components in the
device could get damaged.
■
Observe the information on wiring.
■
Carefully check the wiring prior to switching on the device.
NOTE
Control the serial data interface in the device with the API functions. In order to activate
the serial data interface, use an installed SensorApp which contains this function.
Wiring data interfaces via a connection module
Connection modules
Data interface
Reference
6.5.4
Wiring the CAN interface
NOTE
Control the CAN data interface in the device with the API functions. In order to activate
the CAN data interface, use an installed SensorApp which contains this function.
Wiring CAN interfaces via a connection module
Connection modules
Interface
Reference
CDB650-204
CAN
see "Wiring the CAN interface of
the device in the CDB650-204",
page 53
CDM420-0006
CAN
see "Wiring the CAN interface of
the device in the CDM420-0006",
page 63
6.5.5
Wiring the digital inputs
The device has 2 switching digital inputs (Sensor1, Sensor 2). IN/OUT 3 ... 6 can also
be used as digital inputs.
Functions (examples)
•
Start and end external reading cycle.
•
Feed in incremental signal.
Position of digital inputs
•
Male connector of the device (M12, 17-pin, A-coded)
•
Adapter cable (female connector, M12, 17-pin, A-coded/male connector, D-Sub-
HD, 15-pin)
•
Open end of the adapter cable (female connector, M12, 17-pin, A-coded/open
end)
All digital inputs are available at the individual positions.
ELECTRICAL INSTALLATION
6
8019943/1EJ6/2022-02 | SICK
O P E R A T I N G I N S T R U C T I O N S | InspectorP64x/65x
35
Subject to change without notice