67
8012707/ZVF9/V2-1/2019-04 | SICK
O P E R A T I N G I N S T R U C T I O N S | GM32
Subject to change without notice
SPECIFICATIONS
9
9.2.3
Sender/receiver unit
9.2.4
Open measuring probe (GMP)
9.2.5
Gas-testable measuring probe (GPP)
Description
Analyzer unit of the measuring system
Operation
Via integrated control unit
Dimensions (W x H x D)
315 mm x 580 mm x 359 mm
Weight
20 kg
Table 22: Technical data sender/receiver unit
Description
Measuring probe in open design version with integrated purge air
guidance system
Process temperature
≤
+550 °C
Versions for higher temperatures on request
Process pressure
–60 hPa ... 60 hPa
Relative
Dimensions (W x H x D)
See dimension drawings
Weight
25 kg
Material, media contact
Stainless steel 1.4571, stainless steel 1.4539
Auxiliary gas connections
Purge air
Built-in components
Pressure sensor (not in Ex version)
Temperature sensor PT1000 (not in Ex version)
Flow monitor (purge air feed monitor, not in Ex version)
Table 23: Technical data open measuring probe (GMP)
Description
Measuring probe with gas permeable filter element for adjustment
with test gas
Process temperature
With ceramic filter:
≤
+430 °C
With teflon filter:
≤
+200 °C
Process pressure
–60 hPa ... 60 hPa
Relative
Dimensions (W x H x D)
See dimension drawings
Weight
45 kg
Material, media contact
Stainless steel 1.4571, stainless steel 1.4539, ceramic, PTFE
Power supply
Voltage
Frequency
Power input
115 V / 230 V
50 Hz / 60 Hz
≤
150 W
Auxiliary gas connections
Test gas
Purge air
Built-in components
Pressure sensor
Temperature sensor PT1000
Table 24: Technical data gas-testable measuring probe (GPP)