48
8012707/ZVF9/V2-1/2019-04 | SICK
O P E R A T I N G I N S T R U C T I O N S | GM32
Subject to change without notice
6
MAINTENANCE
6
Maintenance
6.1
Maintenance plan (operator)
6.1.1
Recommended expendable and wearing parts for 2 years operation
6.2
Preparation work
Maintenance task
Reference
w
[1]
[1] w = weekly, q = quarterly, h = every half year, y = yearly
q
Visual inspection
see “Visual inspection”, page 49
x
x
x
Cleaning the window
see “Cleaning the window”, page 50
x
x
x
Checking the desiccant cartridges, replace when
necessary.
Replace at the latest after 6 months.
see “Checking and replacing the desic-
cant cartridges”, page 50
x
x
x
Renewing the activated charcoal sachet
SICK Service
x
Checking the purge air unit (for GMP probe)
see “Cleaning the purge air unit”, page
53
x
x
x
Checking optical alignment
see “Alignment check (automatic opti-
cal alignment check; option)”, page 45
x
x
x
Table 11: Maintenance plan
Spare part
Number
Part number
[1]
[1] Per piece
Sender lamp
2 pcs
2082776
Sender lamp GM32 LowNOx
2 pcs
2086187
Desiccant cartridge
8 pcs
2010549
Activated charcoal bag
2 pcs
5323946
Optical cleaning cloth
8 pcs
4003353
Filter insert for purge air unit
8 pcs
5306091
Table 12: Expendable and wearing parts
NOTE: Some tasks cause the GM32 to switch to malfunction
▸
Activate
Maintenance mode
before starting work,
NOTE: Do not switch the purge air off
!
▸
Do not switch the purge air unit off as long as the SR-unit is still on the gas duct.
NOTE: With the GPP probe: Danger of condensation
!
▸
Do not switch off the heater of the GPP probe as long as the probe is in the gas duct.