Alpha mounting angle (
α
)
–y
+y
–x
+x
1
2
3
4
5
α = 270°
α = 90°
α = 180°
α = 0°
Figure 8: Mounting bracket
α
1
Coordinate system of the field of view
2
Angle
α
= 0° (default value), direction of motion according to + y
3
Angle
α
= 90°, direction of motion according to - x
4
Angle
α
= 180°, direction of motion according to - y
5
Angle
α
= 270°, direction of motion according to + x
5.4
Mounting the device
1.
Mount the device in a suitably prepared mounting system with M5 screws using
the threaded mounting holes or sliding nuts provided.
°
Screw the screws no more than 5 mm into the threaded mounting holes or
sliding nuts.
°
Use the threaded mounting holes in pairs on the top or bottom of the device
or the two sliding nuts on the side of the device.
°
Attach the separately-ordered, optional SICK mounting system using the slid‐
ing nuts on the device. Mounting systems are available as accessories,
.
2.
Align the device taking into consideration the field of view (
values during operation", page 50
) and the application circumstances (
"Installation requirements", page 19
).
3.
Connect the device to interfaces and supply voltage when disconnected from
voltage,
see "Connecting the device", page 29
✓
The
Ready
status LED lights up green.
4.
Perform fine adjustment.
MOUNTING
5
8024289/1E1C/2022-09-09 | SICK
O P E R A T I N G I N S T R U C T I O N S | GLS621
23