Working dis‐
tance [mm]
Horizontal
field of view
[mm]
Vertical field
of view [mm]
Effective ver‐
tical field of
view [mm]
V
max
[m/s]
1)
Shutter time
[
μ
s]
Brightness
Maximum trans‐
port speed of the
AGV
LECT
O
R
SI
CK
62
1
70
34.1
42.7
85.3
4.4
160
1.4
100
51.1
63.9
106.5
5.0
140
2.8
120
62.4
78.0
120.6
5.0
140
3.6
150
79.4
99.2
141.8
5.0
140
5.8
250
135.9
169.9
212.5
2.1
335
5.8
1)
V
max
[m/s] = maximum overspeed [m/s]
Table 6: Use of individual Data Matrix codes
1)
Working dis‐
tance [mm]
Horizontal
field of view
[mm]
Vertical field
of view [mm]
Recom‐
mended
code resolu‐
tion [mm]
V
max
[m/s]
2)
Shutter time
[
μ
s]
Brightness
Maximum reading
field width
Rea
dy
Resul
t
LED
Dat
a
LN
K
TX
LECT
OR
SI
CK
62
1
70
42.7
34.1
0.4
1.4
110
1.4
100
63.9
51.1
0.5
2.2
160
1.9
120
78.0
62.4
0.6
2.6
175
2.5
150
99.2
79.4
0.8
3.3
185
3.6
250
169.9
135.9
1.3
3.9
335
5.8
Maximum trans‐
port speed of the
AGV
LECT
O
R
SI
CK
62
1
70
34.1
42.7
0.4
1.8
110
1.4
100
51.1
63.9
0.5
2.8
160
1.9
120
62.4
78.0
0.6
3.4
175
2.5
150
79.4
99.2
0.8
4.3
185
3.6
250
135.9
169.9
1.3
3.9
335
5.8
1)
Valid for Data Matrix codes with icon size 14 x 14 cells.
2)
V
max
[m/s] = maximum overspeed [m/s]
ANNEX
13
8024289/1E1C/2022-09-09 | SICK
O P E R A T I N G I N S T R U C T I O N S | GLS621
51