The device can be aligned in the X- and Y-axes.
•
The mounting device must be able to bear the weight of the device and connecting
cables without shock.
•
Mounting options must be available for the 4 threaded mounting holes or the 2
sliding nuts.
5.3
Mounting location
5.3.1
Determining alignment
Alignment at maximum reading field width:
Rea
dy
Resul
t
LED
Dat
a
LN
K
TX
LECT
OR
SI
CK
62
1
Figure 6: Mounting in direction of motion of the AGV
Alignment at maximum transport speed of the AGV:
LECT
O
R
SI
CK
62
1
Figure 7: Mounting opposite to the direction on motion of the AGV
The selected alignment effects the speed of the AGV and the size of the field of view
depending on the set working distance and the 2D codes used,
values during operation", page 53
.
5.3.2
Working distance
The possible working range for reading is 70 mm to 500 mm. These values refer to the
reading of a Data Matrix code with a resolution of 0.7 mm. The working distance is
measured starting from the housing edge.
MOUNTING
5
8024289//2019-08-15 | SICK
O P E R A T I N G I N S T R U C T I O N S | GLS6
23
Subject to change without notice