NOTICE
Risk of damage to the memory card
To avoid damaging an optional memory card that may be present in the device, make
sure there is no power to the device when you remove or insert it.
1.
Switch off the supply voltage to the device that is to be replaced.
2.
Mark the position and alignment of the device on the bracket or surroundings.
3.
Disconnect and remove all connecting cables from the device.
4.
Detach the device and remove from the bracket.
5.
Backed-up configuration data: if an optional memory card was installed in the
device, removed the memory card with the backed-up parameter set. The memory
card is located behind the side cover,
Putting the replacement device into operation:
1.
Backed-up configuration data: install the optional memory card from the device
that is to be replaced in the replacement device of the same type.
2.
Mount and align the replacement device (
). When doing
so, note the previously applied markings on the bracket or surroundings.
3.
Reconnect the connecting cables to the replacement device (
4.
Switch on the supply voltage for the replacement device.
✓
The replacement device starts with the default setting and searches for external
storage medium with a valid parameter set. Depending on the success of the
search, the replacement device proceeds as follows:
°
If the replacement device detects a memory card, it transfers the valid para‐
meter set from this storage medium to its permanent memory and operates
in accordance with its configuration data.
°
If the replacement device does not detect any external storage media, it will
start with its last permanently stored parameter set. In the case of devices
that have not been used before, this corresponds to the factory default set‐
ting.
5.
Establish a connection with the replacement device using the SOPAS ET configura‐
tion software.
6.
Transfer the configuration data of the device to be replaced saved on the PC to the
replacement device by downloading and permanently store this data.
9
TROUBLESHOOTING
46
O P E R A T I N G I N S T R U C T I O N S | GLS6
8024289//2019-08-15 | SICK
Subject to change without notice