3.3.1.1
Illumination unit
1
3
2
1
1
1
Figure 2: Illumination unit (integrated illumination unit)
1
4 x LED (2 x left / 2 x right)
2
Feedback LED (e.g. for Good Read) = 1 x green LED
3
Aiming laser for alignment, can be deactivated = 2 x red laser LEDs
NOTE
Do not look into the viewing window of the device in order to avoid dazzling from the
integrated illumination unit.
3.3.2
Display and operating elements
Ready
Read Diagn
Result
TeachIn
LED
Auto-Setup
Data
Autofocus
LNK TX
Userdefined
300
200
100
70
40
100
0
[mm]
[%]
O
O
O
O
O
Figure 3: LED status displays and bar graph on the top of the device
Status displays in read mode
Table 4: First display level
Display
LED
Color
Status
Ready
Lights up Green
Device is ready
Lights up Red
Hardware or software error
Result
Lights up Green
Read operation successful
Lights up Red
Read operation unsuccessful
LED
Lights up Green
Read mode: illumination on, internal reading interval open
Data
Lights up Yellow
Data output via host interface
LNK TX
Flashing
Green
Data traffic via Ethernet
Functions
Table 5: Function overview
Function
Description
Read Diagn
(read diag‐
nosis)
Percentage analysis: The device records a series of images and uses
the current reading performance settings to decode them. With the
0 ... 100% bar graph, the device shows the read rate of the last 10%
(90% to 100%).
The bar graph display is activated in standard read mode.
PRODUCT DESCRIPTION
3
8024289//2019-08-15 | SICK
O P E R A T I N G I N S T R U C T I O N S | GLS6
15