119
8024493/AE00/V1-0/2020-09| SICK
O P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER SP100 Ex-2K
Subject to change without notice
TECHNICAL DATA
15
DHSP-TxxxxEx-2K sender/receiver unit (Zone 1/21)
Table 28: Technical data sender/receiver unit DUSTHUNTER SP100 Ex-2K
Connection line with Ex-Plug-Connector
Table 29: Technical data, connection line with Ex-Plug-Connector
Ambient temperature
-40 °C … +60 °C
Ex approvals
ATEX
IECEX
II 2G Ex db op is IIC T6 Gb
II 2D Ex tb op is IIIC T85 °C Db
Ex db op is IIC T6 Gb
Ex tb op is IIIC T85 °C Db
Protection class
IP66
Weight
Nominal length 435 mm
Nominal length 735 mm
≤
14.2 kg
≤
15.2 kg
Power supply
Voltage
Power consumption
24 V
≤
8 W
Protection class
III
Temperature range
Movable
Fixed installation
-5 °C … +70 °C
-40 °C … +80 °C
Minimum bending radius
Movable
Fixed installation
15 × line diameter
6 × line diameter
Available lengths
5 m / 10 m / 25 m / 50 m / 100 m
Other lengths on request
Line type
Lappkabel, Unitronic Li2YCY v (TP) 2 mm²×2 mm²×0.5 mm²
Burning behavior
Flame-retardant acc. to IEC 60332-1-2