Important information
DANGER
Hazard due to lack of effectiveness of the protective device
Persons and parts of the body to be protected may not be recognized in case of non-
observance.
b
Only mount deflector mirrors to solid walls or machine components. The position
of the deflector mirrors must not change after alignment.
b
Do not use deflector mirrors if contamination, beading water, condensation, or
frost on the deflector mirrors is to be expected.
b
Make sure that the deflector mirrors are intact and free of scratches, contamina‐
tion, beading water, condensation, frost, etc. at all times.
Further topics
•
15.3.2
Change in scanning range using deflector mirrors
NOTE
The use of deflector mirrors reduces the sensing range depending on the number of
deflector mirrors in the light path.
Table 20: Scanning range with and without 1, 2, or 3 deflector mirrors
Type
Scanning range,
typical
Scanning range
with 1 deflector
mirror, typical
Scanning range
with 2 deflector
mirrors, typical
Scanning range
with 3 deflector
mirrors, typical
PNS75, PNS125
15.5 m
14 m
12.6 m
11.3 m
15.3.3
Deflector mirror – ordering information
Table 21: Ordering information, deflector mirror
Part
Type code
Part number
Deflector mirror incl. mounting kit
PNS75-008
1026647
15.4
Mirror columns
Table 22: Ordering information, mirror columns
Column
height
Suitable for
number of
beams
Suitable for
beam separa‐
tion
Type code
Part number
985 mm
2
500 mm
PM3S96-00240020
1040619
1,185 mm
3
400 mm
PM3S11-00330030
1040625
1,285 mm
4
300 mm
PM3S13-00430040
1040626
Complementary information
Observe the information on deflector mirrors, particularly on changing the scanning
range.
Further topics
•
ACCESSORIES
15
8021554/14Q7/2020-04-27 | SICK
O P E R A T I N G I N S T R U C T I O N S | deTem2 Core IP69K
59
Subject to change without notice