![SICK CLP 100 Operating Instructions Manual Download Page 42](http://html.mh-extra.com/html/sick/clp-100/clp-100_operating-instructions-manual_1264218042.webp)
Chapter
10
Operating Instructions
CLP 100 Bar Code Reader
Appendix
42
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 912/0000/21-08-2002
Data/Parity/Stop
Bits
UH0P
0: 7O1
1: 7O2
2: 7E1
3: 7E2
4: 8N1
5: 8N2
6: 8O1
7: 8O2
8: 8E1
9: 8E2
10: 7N1
11: 7N2
Terminator
UH0T
0: NONE
1: <SX>/<EX>
2: /<CR><LF>
3: /<CR>
4: <SX>/<EX><CR>
5: <EX>/<CR>
Cs Control
UH0H
0: NO CONTROL
1: CONTROL
Error String
UH0R
0: NOT SEND
1: BR
2: ?
3: <CAN>
4: ERROR
Result Output Time
UE
00:
HOLD
1-99: 10-990 ms
10:
100 ms One Shot
Result Function
UJ
0: DISABLED
1: GOOD READ
2: NO READ
Result Output
Timing
UF
0: AFTER READ
1: AFTER SENSOR OFF
MemoryM
0: DEFAULT
1: RECALL N. V. MEMORY
2: WRITE N. V. MEMORY
Multiple Reads
X
1-10: 1-10 Times
2:
2 Times
End Of Reading
Interval
Y
0: GENERATED BY TRIGGER
Y1,nn: 01-99 BY TIMER
Debouncing Sensor
UY
0: 1 ms
1: 5 ms
2: 10 ms
Codabar Start/Stop
Character
US
0: LOWER CASE
1: UPPER CASE
Separator
UT
0: NONE
1: &
2:
3: FS
4: GS
5: SP
Parameter
Character
Value
Tab. 10-3: Command language for CLP bar code readers