Data sheet CLP 100
Type
CLP 100
Scanner design
CCD bar code reader
Light source
Visible red light (
λ
= 630 nm)
Artificial light compatability0 ... 100,000 lux
Scanning/Decoding frequency500 Hz
Reading distance/Resolution
30 ... 40 mm:
0.15 mm
25 ... 45 mm:
0.2 mm
25 ... 45 mm:
0.25 mm
25 ... 55 mm:
0.35 mm
25 ... 55 mm:
0.5 mm
25 ... 55 mm:
1 mm
Reading area width
80 mm (at a reading distance of 40 mm)
Minimum resolution
0.125 mm
Code types
All common bar codes
Optical displays
Status display with two LEDs (red and green)
Data interfaces
2 x (RS-232)
Data transfer rate
1,200 ... 19,200 Bd
Supply voltage
5 V DC
±
5 %
Power consumption for reading
operation
350 mA
Power consumption for standby
mode
150 mA
Housing
Metal
Enclosure rating
IP 40
EMC test
In accordance with IEC 801
Weight
Approx. 200 g
Temperature
(ambient service/storage)
0
°
C ... +40
°
C /
−
20
°
C ... +70
°
C
Maximum relative humdity30 ... 85 %, non-condensing
Tab. 9-1: Technical specification of the CLP 100