6
Commissioning
6.1
Setting the zero angle position
The zero angle position between the sensor and magnet can be set either via the cable
or IO-Link.
Setting the zero point via cable:
1.
Connect pin 2 to the voltage supply “L+” for at least two seconds.
2.
LED 1 begins to flash
3.
Within 3 seconds connect pin 2 to ground or leave the connection open (unde‐
fined level)
4.
Position successfully taught in. LED 1 lights up constantly for five seconds
5.
If the position was not successfully taught in, LED 1 flashes quickly for five sec‐
onds
✓
The sensor is adjusted and ready for operation.
To configure the device via an IO-Link procedure, read the MAS IODD, document num‐
ber #8024987. A description of the IODD can be found in the Technical Information,
document number #8027789.
The documents are available on the MAS product page in the Internet
PRODUCT NUMBER.
7
Troubleshooting
The Troubleshooting table indicates measures to be taken if the sensor stops working.
Table 8: Troubleshooting
LED/fault pattern
Cause
Measures
Green LED does not light up
Voltage interruptions outside
the permissible range
Ensure there is a stable power
supply in accordance with the
technical specifications
Yellow LEDs are flashing.
No magnet detected.
Place the magnet on the
active surface of the sensor.
Green LED is pulsating.
IO-Link communication
-
All LEDs are flashing quickly.
Find me
function is activated
-
8
Disassembly and disposal
The sensor must be disposed of in line with applicable country-specific regulations.
When disposing of them, you should try to recycle them (especially the precious met‐
als).
OPERATING INSTRUCTIONS
8027419.1GGF/2022-07-01 | SICK
O P E R A T I N G I N S T R U C T I O N S | MAS
25
Subject to change without notice
en
Summary of Contents for 2126478
Page 1: ...O P E R A T I N G I N S T R U C T I O N S MAS Bearingless encoder de en es fr it ja pl pt zh...
Page 2: ...B E T R I E B S A N L E I T U N G MAS Lagerlose Encoder de en es fr it ja pl pt zh...
Page 16: ...O P E R A T I N G I N S T R U C T I O N S MAS Bearingless encoder de en es fr it ja pl pt zh...
Page 30: ...I N S T R U C C I O N E S D E U S O MAS Encoder sin rodamientos de en es fr it ja pl pt zh...
Page 44: ...N O T I C E D I N S T R U C T I O N S MAS Codeurs sans palier de en es fr it ja pl pt zh...
Page 58: ...I S T R U Z I O N I P E R L U S O MAS Encoder senza supporto de en es fr it ja pl pt zh...
Page 72: ...MAS de en es fr it ja pl pt zh...
Page 75: ...1 1 1 Product ID pid sick com P N P N CAD EU 1 2 b 1 2 8027419 1GGF 2022 07 01 SICK MAS 75 ja...
Page 100: ...M A N U A L D E I N S T R U E S MAS Encoder sem alojamento de en es fr it ja pl pt zh...
Page 114: ...MAS de en es fr it ja pl pt zh...
Page 117: ...1 1 1 ID pid sick com P N P N CAD 1 2 b 1 2 2 2 1 8027419 1GGF 2022 07 01 SICK MAS 117 zh...