3
D-Sub HD, 15-pin
4
M12, 17-pin
5
M12, 12-pin
2.
Connect the CDF600-22xx to a 24 V power supply.
3.
Set the rotary encoding switch found on the side of the CDF600-22xx to "2".
To connect using open-ended cables and connection terminals:
1.
Connect the pins according to the table below.
Pin on TriSpectorP1000
(Power I/O connector)
Pin on CDF600-2200
(DEVICE connector)
Connection type
Pin 11
Pin 2
Serial (RX to TX)
Pin 12
Pin 3
Serial (TX to RX)
Pin 2
Pin 5
GND to GND
Pin 1
Pin 1
24 V to 24 V (optional)
1
1
The 24 V to 24 V connection allows the TriSpectorP1000 to be powered by the CDF600-22xx.
2.
Set the rotary encoding switch found on the side of the CDF600-22xx to "2".
Further information
For information about configuration and operation of the CDF600-22xx, see the
CDF600-2xxx product page,
. The following information is
available there:
•
Technical information
•
Function blocks (including documentation) for sending strings to and from the
CDF600-22xx using Profinet and Profibus
ANNEX