Figure 7: Laser (sender) window to the left, camera (receiver) window to the right
The following spare parts are available:
Glass windows
•
Laser window: 2078269
•
Camera window: 2078266
PMMA windows
•
Laser window: 2078268
•
Camera window: 2078267
Mounting instructions
General:
•
Switch off the power to the device before replacing the window.
•
At delivery, the PMMA spare part windows are sealed with a white protective foil.
Remove the foil before replacing the window.
•
Replace the window in a clean area, to avoid getting dust or dirt inside the camera
housing.
To keep the IP67 classification:
•
Make sure that the protective seal around the window is correctly re-assembled.
•
Tighten the screws with a torque of 0.7 - 0.8 Nm.
5.5
Mounting an external trigger sensor (optional)
If the device is triggered by an external trigger sensor, it is recommended to place the
trigger sensor beyond the device (see left image).
Place the trigger sensor so that the distance b between the trigger sensor and the
device is smaller than the distance a between the device and the part of the object
to be inspected Adjust the mounting location of the external trigger sensor so that the
correct part of the object is inspected when the object activates the trigger sensor (see
left image).
The API contains functionality for delaying the external trigger signal. For SensorApps
where this functionality is implemented, the sensor can delay the external trigger signal
so that the mounting of the external trigger is more flexible (see right image).
5
MOUNTING
24
O P E R A T I N G I N S T R U C T I O N S | TriSpectorP1000
8022395/19OK/2020-12 | SICK
Subject to change without notice