80
- User Manual
NOTE2
Thus imposing the capability of the Fish Finder to correctly detect the weakest echoes
coming from a very deep bottom.
5.6.10 Display Setup Menu
The Display Setup Menu allows you to change the color scheme of the Fish Finder display,
adjusts the chart scrolling rate, enables or disables the White Line and allows determining the
graphical representation of fishes.
[MENU] + “Display Setup” + [ENTER]
Color Settings
Allows you to change the color scheme of the Fish Finder display.
The available colors are Blue Background, White Background, Black
Background, Gray Scale and Reversed Gray Scale.
Scrolling Speed
Adjusts the chart scrolling rate. Note that the scrolling rate is limited by
the sound speed and the depth according with the following relation:
the deeper the setting, the slower the scrolling rate. 100% is the
maximum possible.
White Line
Controls how the chart plotter displays information about the bottom
type (hard or soft).
Fish Symbols
Allows determining the graphical representation of underwater
suspended targets: Echo/Echo+Icon/Echo+Icon+Depth/Echo+Depth/
Icon/Icon+Depth. The Fish icons displayed are among four different
shapes depending on the size of the Target (Small, Med, Big, Huge).
Water Temperature
Allows you to choose the Water Temperature label displayed over the
echogram between Primary and External.
5.6.11 Transducer Setup Menu
The Transducer Setup menu contains settings that does not require frequent changes.
[MENU] + “Transducer Setup” + [ENTER]
Keel Offset
It is the transducer depth offset from the surface. This makes
it possible to measure depth from the surface instead of from
the transducer’s location.
Calibrate Sound Speed
Allows calibrating the value of Sound Speed in the water,
depending on the water temperature and salinity.
Calibrate Water Speed
Allows calibrating the value of Water Speed sensor. The
calibration value, in the range between -10% to +10%, will
be applied to the water speed from the transducer.
Calibrate Water Temperature
Allows the calibration on the Water Temperature sensor.
Using the readings from a precise temperature measuring
device, insert here a positive/negative offset to display right
value on Fish Finder screens.
Calibrate Aux Temperature
Allows the calibration of the Aux Temperature sensor. Using
the readings from a precise temperature measuring device,
insert here a positive/negative offset to display right value on
FF screens.
Restore Defaults
Restores the default values.
Sonar Resolution
4 bit / 8 bit
Summary of Contents for SNS-1100
Page 1: ...GPS Chart Plotter USER MANUAL...
Page 2: ......
Page 6: ......
Page 68: ...68 User Manual Quick info on Single Destination Fig 4 4 Quick Info on Destination...
Page 97: ...User Manual 97 2 Connect the wires to the quick disconnect bracket cable as follows...
Page 104: ...104 User Manual External NMEA Connection C COM Connection SNS 700fe SNS 700fi...
Page 109: ...User Manual 109 Autopilot Connection External NMEA Connection...
Page 110: ...110 User Manual External Alarm Connection C COM Connection...
Page 112: ...112 User Manual DIMENSIONS...
Page 113: ...User Manual 113 Notes...