T
-900 series Chapter 5 Equipment
0093142132-00
5-16
Connection of DC Cable (CW-265-2M)
To [POWER] port
GND (Gray)
DC- (Black)
DC+(White)
Grounding
•
Use the large diameter cable for ground wire as possible.
•
Connect the ground wire to the ground material at a shortest distance.
•
When connecting the external equipment whose positive polarity is connected to the ground line, do
not connect the ground of the signal line to the cabinet ground.
Connection with the AIS Receiver (J1) (Prepared by a customer)
Use the CW-376-5M (Optional) when installing the AIS receiver. For connecting any equipment, one
end of the CW-376-5W is left un-treated. Prepare a connector suitable for the equipment you desire to
connect.
The connection cable consists of six core wires and the shield wire around them. A signal is inputted
from the orange (AISIN+) and black (AISIN-) wires.
For the CW-376-5M and connector for connection of AIS receiver, refer to the illustration below.
After soldering, perform the waterproof and insulation treatment on the junction with a self-fusion tape.
AISIN+ (Orange )
AISIN- (Black)
To AIS receiver
Insulate other wires (including the shield wire)