Chapter 1 Basic Operation
T
-900 series
1-1
0093142132-00
Chapter 1
Basic Operation
The basic operation of this unit is as follows. For detailed explanation, refer to each item in this manual.
1 .
1.3 Power On/Off
2 .
1.5 Transmission
1 .
Press the [BRILL] to turn
on the power.
When [ST'BY] appears, press
the [STBY/TX] key to start
the transmission.
5 .
Rotate the [STC] knob to adjust the sea surface reflection suppression effect.
The suppression effect becomes strong when rotating clockwise the knob and
becomes weak when rotating counterclockwise the knob.
・
This function reduces the gain at a near distance. If you turn clockwise the knob
too much, desired objects may disappear. Adjust properly to meet the weather
condition.
Example of STC adjustment :
: The suppression
is too weak.
: Optimum
suppression.
The reflection from sea
surface is displayed.
The desired objects
are displayed.
: The suppression
is too strong.
Some objects are
not displayed.
1.8 STC adjustment
EN
T
ME
NU
RANGE
GAIN
TX
STBY
BRILL