Value
Description
0
Multiply by 1
1
Multiply by -1
Table 9-93 Polarity bits description
9.2.48
Max Profile Velocity Object 0x607F
The value sets the maximum value of the Profile Acceleration Object 0x6083.
Attribute
Value
Name
Max Profile Velocity
Index
0x607F
Subindex
0x00
Type
UNSIGNED32
Access
RW
Default Value
0x4E20 (20,000)
Value range
1
-
Table 9-94 Max Profile Velocity
9.2.49
Profile Velocity Object 0x6081
The value sets the target speed of the drive when Profile position mode (pp) is active.
Attribute
Value
Name
Profile Velocity
Index
0x6081
Subindex
0x00
Type
UNSIGNED32
Access
RW
Default Value
0x0200 (512)
Value range
1
-
Table 9-95 Profile Velocity
9.2.50
Profile Acceleration Object 0x6083
HT7 Ethercat User Guide