Attribute
Value
Type
INTEGER32
Access
RW
Default Value
0
Unit
V
Value range
-
-
Table 9-86 Target Position
9.2.45
Home Offset Object 0x607C
The value indicates the difference between the zero and the home position. When the homing
method is Homing Method 37 (Homing on current position), the Actual Position after the homing
will be as follow:
P o s i t i o n A c t u a l V a l u e
(
0
x
6064
)
=
H o me O f f se t
(
0
x
6074
)
When the method is set to Homing Method 17 (Negative Limit Switch), the drive will move away
from the sensor of the offset quantity.
Attribute
Value
Name
Home Offset
Index
0x607C
Subindex
0x00
Type
INTEGER32
Access
RW
Default Value
0
Value range
-
-
Table 9-87 Home Offset
9.2.46
Software Position Limit Object 0x607D
The object contains the maximum and minimum values for the Target Position Object 0x607A.
If the values are set to ‘0’ the limits will be disabled.
Attribute
Value
Name
Software Position Limit
Index
0x607D
Subindex
0x00
Type
RECORD
Access
RW
Default Value
0x02
Table 9-88 Software Position Limit
HT7 Ethercat User Guide
44
Summary of Contents for EtherCAT HT7
Page 76: ...www shsitalia it info shsbox shsitalia it 15 ...
Page 91: ...www shsitalia it info shsbox shsitalia it 2 5 Digital Inputs 2 6 Digital Outputs 14 ...
Page 92: ...www shsitalia it info shsbox shsitalia it 2 7 Encoder Inputs 15 ...
Page 95: ...www shsitalia it info shsbox shsitalia it 18 ...
Page 110: ...www shsitalia it info shsbox shsitalia it 2 5 Digital Inputs 2 6 Digital Outputs 14 ...
Page 111: ...www shsitalia it info shsbox shsitalia it 2 7 Encoder Inputs 15 ...
Page 124: ...www shsitalia it info shsbox shsitalia it 28 ...