![SHS EtherCAT HT7 User Manual Download Page 59](http://html.mh-extra.com/html/shs/ethercat-ht7/ethercat-ht7_user-manual_1260846059.webp)
Attribute
Value
Name
Supported Homing Method 3
Index
0x60E3
Subindex
0x03
Type
INTEGER8
Access
R0
Default Value
0x25 (37)
Table 9-119 Supported Homing Method 3
9.2.63
Motor Resolution Object 0x60EF
This object sets the motor resolution. The value represents the number of step needed to complete a
motor revolution with a 200step/rev motor.
Attribute
Value
Name
Motor Resolution
Index
0x60EF
Subindex
0x00
Type
UNSIGNED32
Access
RW
Default Value
25600 (0x6400)
Value range see Table 9-121 for possible values
200
25600
Table 9-120 Motor Resolution
Value
Step resolution
200
Full-step
400
Half-step 1/2
800
1/4 step
1600
1/8 step
3200
1/16 step
6400
1/32 step
12800
1/64 step
25600
1/128 step
500
1/2.5 step
1000
1/5 step
2000
1/10 step
4000
1/20 step
10000
1/50 step
20000
1/100 step
Table 121 Motor Resolution Description
HT7 Ethercat User Guide
54
Summary of Contents for EtherCAT HT7
Page 76: ...www shsitalia it info shsbox shsitalia it 15 ...
Page 91: ...www shsitalia it info shsbox shsitalia it 2 5 Digital Inputs 2 6 Digital Outputs 14 ...
Page 92: ...www shsitalia it info shsbox shsitalia it 2 7 Encoder Inputs 15 ...
Page 95: ...www shsitalia it info shsbox shsitalia it 18 ...
Page 110: ...www shsitalia it info shsbox shsitalia it 2 5 Digital Inputs 2 6 Digital Outputs 14 ...
Page 111: ...www shsitalia it info shsbox shsitalia it 2 7 Encoder Inputs 15 ...
Page 124: ...www shsitalia it info shsbox shsitalia it 28 ...