8
generate flames normally. Please
strictly follow the safety distance
requirement, remove all human,
animal or flammable objects in the
danger area.
Fueling
Please fueling with high quality fuel
according to requirement of this
manual
Power and
DMX cable
connection
Make sure power supply in
consistent with the rated voltage of
the equipment, and the socket must
well grounded.
Switch ON the
machine
Please confirm safety lock located at
TEST MODE before switch on the
POWER ON/OFF.
Set DMX
address
Please refer to 5. DMX control.
Compression
Host controller: Press ”pre-heat”
button (light on)
DMX console: switch DMX value of
channel 6 to 50-200
Check device
status in TEST
MODE
Reconfirm safety lock located at
TEST MODE before test. In this
status, igniter will activated, but
there is no flame.
Pressure Relief
Host controller: Press “pre-heat” key
(light off)
DMX console: switch DMX value of
channel 6 to 0-49/201-255
Press the
safety lock to
USER MODE
Before switch to USER MODE, Please
strictly follow the safety distance
requirements, remove all human,
animal or flammable objects in the
danger area.
Pressurise
Host controller: Press” pre-heat”
button (light on)
DMX console: switch DMX value of
channel 6 to 50-200
Input firing
sequence
F1 MAIN
Synchronizarion CIRCLE FLAMER No. 1-10
From 1-15 Steppsequence short 2.4s
F I L E
NO.
Terminal
Monitor
FI RI NG
HEIGHT
31
0.5s
DURTN
F I R I N G
TRIG
DELAY
0.0s
10.0s
1
REPEAT
COUNTS
REPEAT
DELAY
1
1
7
13
2
8
14
3
9
15
4
10
16
5
11
17
6
12
18
MAIN
FILE SELECT
CONFIG
ABOUT
For example, if want to firing
sequence 31
Host Controller: input 31 @sequence
DMX console: channel 5 DMX value
@ 80-81
Firing
Host controller: Press “FIRING” key
DMX console: switch DMX value of
channel 3 to 254-255