2. Nozzle replacement
Change nozzle
Use 14mm outer hexagon socket wrench to disassemble the nozzle, clean the nozzle and nozzle
socket with air gun (air compressor), change a different nozzle and install it.
Nozzle disassemble tool: SFMET944
Ignitor Position Adjustment
After change the nozzle please adjust the ignitor’s position according to below parameters. The
default position when we ship out from factory is for Nozzle M (standard nozzle). When replace
to nozzle L (indoor nozzle) need to remove the ignitor a little bit to the center, makes the
ignitor closer to the fuel stream.
Nozzle
a mm
b mm
Short flame height m
Long flame height m
M
4 0.5
4 0.5
5~7
8~10
L
2.5 0.5
4 0.5
3~5
6~8
Note: Do unplug the power cable when service flamer.